Checks; Chimney Sweep Function - Sime Brava Slim HE 25 T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Brava Slim HE 25 T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.7

Checks

3.7.1

Chimney sweep function

The chimney sweep function is used by the qualified
maintenance technician to check the mains gas pressure, detect
the combustion parameters and to measure the combustion
efficiency required by legislation in force.
This function lasts 15 minutes and is activated by proceeding
as follows:
– if the panel (2) has not already been removed, remove the
two screws (1), pull the front panel (2) forwards and release it
from the top by lifting it
2
– remove the screws (3) securing the control panel (4)
– move the panel (4) upwards (a) but keeping it in the side
guides (5) to the end of travel
– bring it forwards and down (b) until it is horizontal
4
b
3
– close the gas valve
– loosen the screw of the "mains pressure" point (6) and connect
a pressure gauge
80
All manuals and user guides at all-guides.com
1
Fig. 33
a
5
Fig. 34
– open the gas valve
– power the boiler by setting the main switch to "ON"
ON
– press the button
y
for at least 1 second until "SUMMER"
mode
l
has been selected
– press and hold down the buttons
for approximately 10 seconds until the message "Hi" appears
on the display together with the flashing symbols
– press the button
>
to make the boiler operate at maximum
power "Hi" and check that the mains gas pressure value on the
pressure gauge is correct. Take a reading of the combustion
data and measure the combustion efficiency.
– press the button
<
to make the boiler operate at minimum
power "Lo". The message "Lo" will appear on the display
together with the flashing symbols
EN
6
Fig. 35
Fig. 36
<
and
>
at the same time
l
and
n
l
and
n

Publicidad

Tabla de contenido
loading

Tabla de contenido