Load loss accessory Ø 80 mm
Description
Code
90° curve MF
8077450
45° curve MF
8077451
Horizontal extension
8077351
W. 1000 mm
Vertical extension W.
8077351
1000 mm
Wall terminal
8089501
Roof outlet terminal (*)
8091204
(*) The losses of the roof outlet terminal at inlet include the
manifold code 8091400.
for the boiler to operate correctly it is necessary that a
NB:
minimum distance of 0.50 m of the duct is respected with a 90°
inlet curve.
Example: calculation of the load loss of a Brava Slim HE 25 T
boiler (ducts Ø 80 mm).
Accessories Ø 80
Code
mm
Extension W. 1000
8077351
mm (horizontal)
Extension W. 1000
8077351
mm (horizontal)
90° curve
8077450
90° curve
8077450
Wall terminal
8089501
TOTAL
(installation permitted since the total of the load loss of the
accessories used is less than 15 mm H2O ).
72
All manuals and user guides at all-guides.com
Load loss (mm H2O)
Brava Slim HE 25 T
Inlet
Outlet
0,20
0,25
0,15
0,15
0,15
0,15
0,15
0,15
0,10
0,25
0,80
0,10
Load loss (mm H2O)
Quantity
Inlet
Outlet
Total
7
7 x 0,15
-
1,05
7
-
7 x 0,15
1,05
2
2 x 0,20
-
0,40
2
-
2 x 0,25
0,50
2
0,10
0,25
0,35
3,35
400
250
120
Fig. 16
2.13

Electrical connections

The boiler is equipped with a ready wired power cable which is
to be connected to a 230V~50 Hz network.
If this cable needs to be replaced, an original spare must be
requested from Sime .
Therefore only the connections of the original components
as shown in the table are needed. These are to be ordered
separately from the boiler.
DESCRIPTION
External sensor kit (ß=3435, NTC 10KOhm at 25°C)
Power cable (dedicated)
Remote control HOME (open therm)
Remote control HOME PLUS (open therm)
m
CAUTION
The maintenance interventions described must ONLY
be carried out the professionally qualified personnel.
a
DANGER
Before carrying out any interventions described:
– set the main system switch to "OFF"
– close the gas valve
– make sure that no hot parts inside the appliance are
touched.
OFF
To facilitate introduction of the connection wires of the optional
components into the boiler:
– remove the two screws (1), pull the front panel (2) forwards
and release it from the top by lifting it
2
EN
CODE
8094101
6323875
8092280
8092281
Fig. 17
1
Fig. 18