Parameter Setting And Display; List Of Parameters - Sime Brava Slim HE 25 T Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para Brava Slim HE 25 T:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
3.3

Parameter setting and display

To go into the parameter menu:
– from the selected mode (eg. WINTER)
– press the buttons
r
and
t
(for approximately 5 seconds) at
the same time until "PAR 01" (parameter number) and the
value set (0÷4) appears on the display
– press the button
t
to scroll up the list of parameters and
then
r
to scroll down the list
3.4

List of parameters

Type
No.
Description
Index showing boiler power in kW
PAR
01
0 = 25T
Hydraulic configuration
0 = rapid
1 = storage tank with thermostat or heating only
PAR
02
2 = hot water tank with sensor
3 = two programmer
4=instant with solar power input
5 = open vent
Gas Type Configuration
PAR
03
0 = G20; 1 = G31
Combustion configuration
PAR
04
0 = sealed chamber with combustion control
PAR
08
External sensor value correction
PAR
09
Ignition fan speed
PAR
10
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
PAR
11
-- = Disabled
PAR
12
Heating Curve Incline
PAR
13
Minimum Heating Temperature Adjustment
PAR
14
Maximum Heating Temperature Adjustment
PAR
15
Maximum power heating
PAR
16
Heating Post-Circulation Time
PAR
17
Heating Pump Activation Delay
PAR
18
Re-ignition Delay
Domestic Hot Water Modulation with Flow meter
PAR
19
0 = Disabled
1 = Enabled
PAR
20
Maximum power domestic hot water
PAR
21
Minimum power heating/domestic hot water (premixed)
Domestic hot water preheating enabling
PAR
22
0 = OFF; 1 = ON
External relay 1 function
0 = not used; 1 = remote alarm NO; 2 = remote alarm NC; 3 = zone
PAR
23
valve; 4 = automatic filling; 5 = external request; 6 = recirculation
pump; 7 = zone valve with OT; 8 = relaunch pump
All manuals and user guides at all-guides.com
NB:
scrolling movement.
– once the required parameter has been reached, press the
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
screen is displayed.
CONFIGURATION
DOMESTIC HOT WATER - HEATING
holding the buttons
r
or
t
buttons
>
or
<
to modify the value within the permitted range.
The modifications are stored automatically.
t
all at the same time
for at least 5 seconds until the initial
Range
U/M
-
0 .. 5
0 .. 1
-
-5 .. +5
80 .. 160
RPMx25
0 .. +10
-9 .. +5
0 .. 80
20 .. PAR 14
PAR 13 .. 80
0 .. 100
seconds
0 .. 99
x 10
seconds
0 .. 60
x 10
0 .. 60
0 .. 1
0 .. 100
0 .. 100
0 .. 1
0 .. 8
increases the speed of the
r
Step
Default
-
-
0
-
1
2
-
1
0
-
-
0
°C
1
0
1
128
°C
1
3
°C
1
-2
-
1
20
°C
1
20
°C
1
80
%
1
100
1
3
1
0
Min
1
3
-
1
1
%
1
100
%
1
0
-
1
0
-
-
0
77

Publicidad