2: Anti Masking Sensitivity:
" ON " selects a higher level of Anti Masking sensitivity.
" OFF " selects the standard Anti Masking sensitivity.
3: Resetting the "Trouble output":
" ON " resets the Trouble output after alarm.
" OFF " resets the Trouble output only when authorized.
4: How to signal "Trouble output":
" ON " signals the Anti Mask signals on both the TROUBLE and
ALARM relay.
signals the Technical Fault to TROUBLE relay only.
" OFF " signals the Anti Mask and Technical Fault on the ETO.
5: LED indication:
" ON " enables both LED's on the detector at all time.
" OFF " puts both LED's under the control of the Walk test and
Latch input when the system is disarmed.
6: Control voltage (CV) polarity (Fig.
"On" provides the standard Aritech logic with active high logic
to enable Walk Test and Latch inputs.
"OFF" provides "Active Low" logic to enable Walk Test and
Latch inputs.
Preferred settings
To prevent Anti Mask alarms during Armed state (Night
mode), the following settings are preferred:
Switch 1 "ON"
Switch 3 "OFF"
Switch 4 "OFF"
Switch 5 "OFF"
With these settings the Anti Mask alarms are signaled to the con-
trol panel only during Day by the Trouble relay. The LEDs are
controlled by the Latch and Walk Test input. Resetting of the Anti
Masking alarm can only be done in Walk Test mode.
Never show the detector state to intruders via the
LED's .
LED indications are controlled by DIP switch 5
If DIP switch 5 is "ON" then the following indications are
shown at all times.
If DIP switch 5 is "OFF" then the following indications are
only shown when the system is disarmed and the Walk Test
line is enabled.
Detector
Yellow Red Comment
status
LED
LED
Power on
Alarm
----
AM
----
PIR Trouble
----
AM Trouble
----
Low Battery
----
restored.
Latch alarm
----
Reset condition
Detector status
Condition for reset
PIR Alarm
Normally after 3 sec.
PIR Latched alarm
Next change from "Disarm" to "Arm".
AM (auto - reset)
Next successful PIR alarm after a 40 sec.
inhibit period.
All manuals and user guides at all-guides.com
)
= lit
= flashing
Blinks for 20 sec.
For alarm period - nominally 3
sec.
Until Anti Masking reset.
Flashes slowly until reset.
Flashes quickly until reset.
Always ON until correct voltage
Flashing until reset.
(not displayed during Walk Test).
AM (authorised reset) Next successful PIR alarm in "Disarm"
and "Walk test" mode.
PIR Trouble
Next successful PIR alarm.
Next successful automatic test (every 10
minutes during "Disarm").
AM Trouble
Next successful Anti Masking detection.
Next successful automatic test (every 10
minutes during "Disarm").
Selecting the coverage pattern (Fig. )-c)
Change the coverage pattern to fit specific requirements by using
the mirror blinders as shown (Fig.
unused curtains, which might otherwise be looking at walls or
windows close to the detector.
For example:
See Fig. b for the mirror curtain coverage pattern corresponding
to curtain 2A and 2B, 7A and 9B masked.
Removing label(s) can damage the mirror surface!
Note: The range of the detector can, under optimal conditions,
be up to 100% higher than stated.
Window masking (Fig. d)
The window blinder is fitted off-factory to the inside of the window
of the detector, as shown in Fig.
detector looking directly at objects in close proximity (within 1.5 m)
and at those directly under the detector. By partly masking the
curtains in this way, the detector will be more stable during normal
use. When undercrawl detection is required, the blinder should
be removed.
Technical Data (DD477AMC / DD478AMC / DD497AMC /
DD498AMC)
Limited input power -
Peak-to-peak ripple
Current consumption
Normal operation
Alarm
Current consumption
Normal operation
Alarm
Mounting height
Target speed range
Microwave frequency
Maximum microwave
output power at 1.0 m
(Continously)
Alarm output
Tamper output
Trouble Output
Alarm time
Temperature limit
Relative humidity
Size
Weight
Number of zones
Viewing angle
Housing complies
(with sealed cable entry) IP30 IK02
Dual loop
- 4 -
c
). It is recommended to blind
d
. This blinder prevents the
9-15 VDC (12 V nom.) max. 8 A fuse
source
2 V (at 12 VDC)
DD477AMC
DD497AMC
13 mA nom.
13 mA nom.
16 mA max.
16 mA max.
DD478AMC
DD498AMC
14 mA nom.
14 mA nom.
17 mA max.
17 mA max.
min 1.8-max. 3.0 m
min 0.1-max. 4.0 m/s
2450 MHz
2
Enable: 0.005 µW/cm
Disable: 0 µW/cm
2
80 mA at 30 VDC max.
80 mA at 30 VDC max.
80 mA at 30 VDC max.
3.0 sec.
-10 °C to +55 °C
max. 95%
140 x 78 x 68 mm
205 g
DD477AMC/DD478AMC DD497AMC/DD498AMC
9 at 16 m
7 at 20 m
DD477AMC/DD478AMC DD497AMC/DD498AMC
86°
60°
DD477AMC & DD497AMC only