1
General safety notes
2
Notes on UL approval
3
Intended use
4
Operating and status indicators
5
Mounting
8022178.18JF 02.07.2020 | SICK
Subject to change without notice
Read the operating instructions before commissioning.
■
■
Connection, mounting, and configuration may only be performed by trained
specialists.
■
NO
2006/42/EC
Not a safety component in accordance with the EU Machinery Directive.
SAFETY
■
When commissioning, protect the device from moisture, contamination and
UV radiation (sun light).
These operating instructions contain information required during the life cycle of
■
the sensor.
The device must be supplied by a Class 2 source of supply.
UL Environmental Rating: Enclosure type 1
The RAY26 is an opto-electronic photoelectric retro-reflective sensor (referred to as
"sensor" in the following) for the optical, non-contact detection of objects, animals, and
persons. A reflector is required for this product to function. If the product is used for any
other purpose or modified in any way, any warranty claim against SICK AG shall become
void.
1
43
2
LED indicator green: supply voltage active
1
BluePilot blue: AutoAdapt indicator during run mode
2
Teach-in button
3
LED indicator yellow: status of received light beam
4
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of 0.65Nm.
GENERAL SAFETY NOTES
1
5