periodic cleaning

• Every 15 days take out shower and shower-holders located under the coffee groups, and clean
the parts with the brush.
• To assure a better functioning of the machine and to remove any coffee residual from the
erogation solenoid valves and the erogation pipes we recommend to use the cleaning tablets
you find in the equipment of the machine.
1. Change the standard filter with a blind filter you find in the equipment of the machine.
2. Put 1 cleaning tablet into the blind filter.
3. Press the * buttom of the group you need to clean for 10 sec.
4. All leds of the group will start blinking.
5. Wait for the end of cycle (3 min).
6. Take out the filterholder, the blind filter and put the standard filter in.
7. Press the * buttom for 10 sec to start a rinsing cycle. Wait for end of the cycle. From now
on you can dispense coffee. Repeat the same operation to clean the other groups.
Reassemble parts carefully. Wrong reassembling can cause bad coffee and damage of the coffee
groups.
water softener maintenance
If the machine is attached to a water softener, see the water softener instructions manual. The ma-
nufacturer and the installer cannot be held responsible for damage caused by lack or improper main-
tenance of the water softener.