2. Installation
Remove the furnace components from their packaging and place them on a suitable
table. Please observe the instructions on the outer packaging. Make sure the voltage
indicated on the rating plate complies with the local power supply. If this is not the case,
the furnace must not be connected.

Power connection

Please make sure that the voltage indicated on the rating plate complies with the
local power supply. Subsequently, connect the power cord (2) with the power socket
of the furnace (1).
The device must only be operated with the supplied original power cord or a
replacement cord with the same specifications.
Vacuum pump connection
Connect the vacuum pump plug (4) with the vacuum pump socket (3). We
recommend using a vacuum pump from Ivoclar Vivadent, since these pumps are
especially coordinated with the furnace. If other pumps are used, always observe and
do not exceed the maximum power consumption specified on the rating plate at the
rear of the device. Connect the vacuum hose (6) with the vacuum hose connection
(5).
Switching on
Connect the power cord with the power supply. Put the On/Off switch (7) at the rear
of the device on position "I". After the self test of the device, the program indicator
or the last selected program appears on the screen.
Removing the transport safety film
Open the furnace head using the key OPEN FURNACE HEAD. Remove the protective
film from the cooling plate.
Please check the surfaces for adhesive residue. Any adhesive residue
must be removed.
Placing the object tray
Place the object tray (8) on the object tray rest in the firing chamber (9).
6
3
1
4
5
2
6
8
7
9