Power
Nominal 24 V DC at max. 550 Ohm
• Maximum 30 V DC
• 4 to 20 mA
Approvals
• General
CSA
US/C
• Radio
Europe (R&TTE), FCC, Industry Canada
• Hazardous Intrinsically Safe
Non-incendive
• Marine
Lloyd's Register of Shipping
ABS Type Approval
Approved dust-tight and water-tight conduit seals are required for outdoor Type 4X /
Note:
NEMA 4X, Type 6 / NEMA 6, IP67, IP68 locations.
EN61000-4-3 (CE EMC) testing was conducted on the SITRANS Probe LR while
Note:
mounted in a metallic vessel.
Mechanical
• Process
Connections: threaded connection
• Antenna:
polypropylene rod
Process
• Temperature (at process connection):
• Pressure (vessel):
1.
Wiring Drawing: Intrinsically Safe (FM )
See
or
Wiring Drawing: Intrinsically Safe (CSA)
2.
Wiring Drawing: Non-incendive (FM)
See
A5E32106153
SITRANS Probe LR – QUICK START MANUAL
All manuals and user guides at all-guides.com
, FM, CE, C-TICK
(Europe)
(US/Canada)
(International) IECEx SIR 13.0005X Ex ia IIC T4 Ga
(Brazil)
(US)
40 to +80 °C (40 to +176 °F)
maximum 3 bar, gauge (43.5 psi, gauge)
on page 2 of Appendix A, for drawing number 23651611,
on page 3 of Appendix A, for drawing number 23651621.
on page 1 of Appendix A, for drawing number 23650537.
ATEX II 1 G Ex ia IIC T4 Ga
1
FM/CSA
: (barrier required)
Class I, Div. 1, Groups A, B, C, D
Class II, Div. 1, Groups E, F, G
Class III
T4
INMETRO: DNV 12.0068 X
Ex ia IIC T4 Ga
IP67/IP68
-40 ºC
T a
+80 ºC
DNV #OCP 0017
ABNT NBR IEC 60079-0:2008 e
ABNT NBR IEC 60079-11:2009 e
ABNT NBR IEC 60079-26:2008
2
FM
:
Class I, Div. 2, Groups A, B, C, D
1.5" NPT, BSP , or G (BS EN ISO 228-1)
hermetically sealed construction
T5
Page EN-3

Publicidad

Tabla de contenido
loading