Technical Data; Gas Heated Bain-Marie Minima Series, Ctg.ii (Natural Gas And L; Technical Characteristics - MBM MINIMA Serie Instrucciones Para La Instalación, El Uso Y El Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.
1.1
GAS HEATED BAIN-MARIE MINIMA SERIES, CTG.II (NATURAL GAS AND L.P.G.)
EXTERNAL
BAIN-MARIE
MODEL
L x P x A*
400x600x290
G B M 4 6
600x600x290
G B M 6 6
* Total Height 480 mm.
1.2

TECHNICAL CHARACTERISTICS

- STAINLESS STEEL FRAME AISI 304, mounted on 18/10 stainless steel height-adjustable feet and with a rubber support top.
- TUB made of stainless steel AISI 304 suitable to be fitted with GASTRONORM trays in the relative modules.
- GAS HEATING by means of self-adjusting flame burner made of stainless steel AISI 304. Thermostat controlled tempera-
ture with safety valve and thermocouple for the automatic interruption of gas supply in case of accidental extinguishment
of the Targhet pilot burner. Piezoelectric ignition of pilot.
SIZE IN mm.
TUB
Vol. Min.
L x P x A
lt.
2 GN 1/6
305x425x170
2,5
2 GN 1/4
1 GN 1
510x470x170
3,5
2 GN 1/6
TOTAL
THERMAL
CAPACITY
LITTLE TUBS
(Hi)
Ltr.
k W
2,15
10
20
5,0
- 13 -

TECHNICAL DATA

GAS CONSUMPTION (15°C)
L.P.G.
NATURAL GAS
NATURAL GAS
G30/G31
H
L
G20
G25
3
m
g/h
m
/h
169 / 167
0,265
0,228
394 / 388
0,616
0,529
NET
WEIGHT
3
/h
kg.
22
30
GB

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

BagnomariaGbm46Gbm66

Tabla de contenido