Changing Location; Disposal And Scrapping; Substances Hazardous To Water; Replacement And Wearing Parts - Bosch CRI/CRIN SST Instrucciones De Funcionamiento

Juego de comprobación para medición carrera a carrera
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

9.
Decommissioning
9.1

Changing location

If the CRI/CRIN SST is handed over to someone else,
hand over all the documentation included in the
scope of delivery as well.
Only transport the CRI/CRIN SST in its original or
equivalent packaging.
9.2

Disposal and scrapping

9.2.1

Substances hazardous to water

!
Oils and greases as well as refuse containing oil
and grease (e.g. filters) represent a hazard to
water.
1. Substances hazardous to water must not be
allowed to enter the sewage system.
2. Substances hazardous to water must be disposed
of in accordance with the applicable regulations.
!
Test oil conforming to ISO 4113 is classified under
waste oil collection category 1. Category-1 waste
oil must not contain any foreign substances such as
waste oil of a different category, gasoline or diesel.
See the test oil safety data sheet for the correct
waste code number.
9.2.2
CRI/CRIN SST and accessories
1. Disconnect the CRI/CRIN SST from the mains and
detach the power cord.
2. Dismantle the CRI/CRIN SST and sort out and
dispose of the different materials in accordance
with the applicable regulations.
Robert Bosch GmbH
Decommissioning | CRI/CRIN SST | 27 |
10. Replacement and wearing
parts
Designation
Adapter for CRI with adapter nut M12  x  1.5
and M14 x 1.5
<)
Adapter for CRIN with adapter nut M12 x 1.5
and M14 x 1.5
<)
Adapter nut M12 x 1.5
<)
Adapter nut M14 x 1.5
<)
Pressure sensor
<)
Adapter for pressure sensor
<)
Connecting cable for pressure sensor
USB connecting cable (5 m)
<)
Sealing cone (6x)
<)
Wearing part
<)

11. Technical data

Designation
Test pressure max.
Pressure sensor maximum pressure
Pressure sensor voltage supply
Actuation electronics voltage supply U
Injections per minute
Total actuation time of
the actuation profile

12. Glossary

The following abbreviations are used in these
instructions:
EPS 815
Injection pump test bench
Continuous quantity analysis
KMA
CRI
Passenger car common-rail injector
CRIN
Commercial-vehicle common-rail injector
bar
1 bar = 0.1 MPa = 100 kPa = 100,000 Pa
Pa
1 pascal = 0.01 mbar
1 newtonmeter = 1 ft lb
Nm
en
Order number
1 685 720 306
1 682 720 308
1 683 345 051
1 683 345 052
1 687 231 914
1 681 398 035
1 684 462 557
<)
1 684 465 563
1 683 387 114
Value
220 MPa
300 MPa
12 VDC
14 VDC  28 VDC  0.5
Bat
1002000
150 µs  3000 µs
|
1 689 989 098
2021-02-24

Publicidad

Tabla de contenido
loading

Tabla de contenido