2. Remove the screws that hold the belt shield and
remove the belt shield.
3. Loosen the nuts on the lift strut.
4. Turn the lift strut to extend the stay or make it
shorter. Extend the stay to lift the rear edge of the
cover. Make the stay shorter to lower the rear edge
of the cover.
5. Tighten the nuts on the lift strut when the adjustment
is done.
6. Do a check of the parallelism. Refer to
check of the parallelism of the cutting deck on page
26 .
7. Attach the belt shield and tighten the screws.
8. Attach the right footrest plate and the front cover.

To remove the BioClip plug

Remove the BioClip plug to change a Combi cutting
deck from BioClip to rear discharge of the grass.
844 - 009 - 25.11.2021
To remove and attach the BioClip plug on
cutting deck Combi 103 and 112
1. Put the cutting deck in servicing position.
2. Remove the 3 screws that hold the BioClip plug and
remove the plug.
3. Attach 3 M8x15 mm screws in the screw holes for
the BioClip plug to prevent damage to the threads.
4. Put the cutting deck back in mow position.
5. Attach the BioClip plug in the opposite sequence.
To remove and attach the BioClip plug on
cutting deck Combi 94
1. Put the cutting deck in servicing position.
2. Remove the 3 screws that hold the BioClip plug and
remove the plug.
3. Put the cutting deck back in mow position.
4. Attach the BioClip plug in the opposite sequence.

To examine the blades

To do a
1. Put the cutting deck in servicing position.
CAUTION:
Damaged or incorrectly
balanced blades can cause damage to the
product. Replace damaged blades. Let an
approved service agent help you sharpen
and balance blunt blades.