Ecolab EcoAdd Instrucciones De Servicio página 334

Ocultar thumbs Ver también para EcoAdd:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 838
Control/software
Fault prevention
Exporting a configuration
Fig. 74: Exporting a configuration
1.
Function
ð Screen changes to [Configuration] USB export / USB import.
2.
[Select USB export] (item 1).
ð The screen shows the export process (item 2). Once complete, the screen
switches to a status screen (item 3).
3.
Press the
4.
Pressing the
MAN046939 Rev. 6-10.2021
1
Ä Further information on page 128 .
During the export process, an available pump code is also transferred.
When importing a configuration, refer to the descriptions
information on page 128 .
The exported configuration is located on the USB stick at the
path: /ECOADD/EXPORT
button (item 4) to return to the [Main menu].
button again returns to the [Operating display].
If a production code is not specified in the import file, there
is a risk that, for example, incorrect material pairings could be
transferred to the pump that do not correspond to the actual
data.
This could lead to incompatibility with the dosing medium
(premature wear).
To avoid such cases, the import is not permitted and the
program issues a corresponding warning (see left).
2
130
4
3
Ä Further

Publicidad

Tabla de contenido
loading

Tabla de contenido