Ecolab EcoAdd Instrucciones De Servicio página 393

Ocultar thumbs Ver también para EcoAdd:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 838
Applies only to EcoAdd:
When calibrating the pump, the metering frequency at 100% is varied so that
the nominal metering capacity [l/h] is always met, irrespective of component
tolerances or on-site conditions. The actual metering frequency at 100% may
therefore be less than the "Max. metering frequency" specified in the technical
data.
NOTICE!
Tightening torques
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity of
the thread. The tightening torques are also given on an adhesive label that is
affixed to the pump head.
Pump head size
Tightening torque of the suction/pressure valves:
Tightening torque of the metering head screws:
Materials
Housing: PPO (Noryl)
n
Metering head: PP, optionally PVDF, stainless steel 1.4571
n
Diaphragm: PTFE - EPDM composite diaphragm
n
Seals: FKM or EPDM, optionally PTFE or FFPM (Kalrez)
n
Valve balls: Ceramic, optionally PTFE or stainless steel 1.4401
n
Valve springs: Hastelloy C4
n
Colour: Blue, RAL 5007
n
Special versions are available on request.
Packaging
Data
Packaging size (L x W x H)
Weight (depending on pump design)
Due to the low weight, no special lifting gear is required during transport.
5 l/h and 11 l/h
2 ± 0.2 Nm
3,75 ± 0.25 Nm
189
Technical data
30 l/h and 50 l/h 120 l/h
2,8 ± 0.2 Nm
4 ± 0.2 Nm
6 ± 0.25 Nm
6 ± 0.25 Nm
Value Unit
395 x 290 x 360 mm
3,5 - 6 kg
MAN046939 Rev. 6-10.2021