Description; Physical Contents - MSA V-TEC io1 Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

US
2

Description

The V-TEC io1 system consists of a V-TEC PFL and a permanently integrated io1 component on the snaphook that monitors
and communicates connection status between the snaphook and an MSA harness with an RFID tag attached.
This manual covers instructions and warnings on installation of the V-TEC io1 system and use of the io1.
Reference the V-TEC PFL manual, P/N 63011-96, included in the box, for instructions and warnings on use of the V-TEC PFL
to which the io1 is connected.
Wake Mode
Motion wakes the io1 from sleep mode. During wake-up, a 15 second countdown to alarm starts and the io1 pulses red LEDs
until a connection is made.
If a connection is present when awake, the io1 pulses a green LED to indicate a good connection.
During a connection event, a tri-tone is played to signal connection. No alarms are sounded during the connected period.
If a disconnection occurs when awake, the io1 counts down a timer and goes into alarm sequence. Once the timer expires, the
io1 beeps 90 dB alarm sounds and blinks red lights.
See
Table 1
for more information on io1 status indicators.
Sleep Mode
The io1 is calibrated to fall asleep when no movement is sensed. This allows the io1 to fall asleep naturally when it should,
such as an order picker stepping off of the Order Picker-type PIT and leaving the io1 to rest.
2.1

Physical Contents

Component
V-TEC io1
Charging Line Components
includes battery, wires, connector/adapter, cable ties, peel
and stick cable tie mounts
RFID Tag/Screws
V-TEC PFL User Instructions
V-TEC io1 User Instructions
Part Number
10213901 (non-swivel snaphook)
10213902 (swivel snaphook)
10215631
10215626
63011-96
10215637
2 Description