Enter the Parameter Menu
Unlock the control panel, if locked.
1.
Press and hold the SET
2.
If necessary, press the SET
3.
Alter Parameter Value
Note: Your POLAR appliance has been preset with default parameters generally deemed suitable for normal operation (see "Default
Parameter Values" on page 4). POLAR recommend these preset values are used.
To alter the value, (if necessary):
With the desired parameter displayed, alter the value using the UP
1.
Press the SET
button to store the value.
2.
Note: The control panel will automatically move to the next parameter. To return to standby mode allow the control panel to time
out.
Parameter Descriptions
Parameter
Name
d1
Operating temperature
Temperature
d2
Differential
d3
Temperature Range
d4
Compressor Activation
d5
Time Intervals
Maximum Temperature
d6
Differential Alarm
Temperature
d7
Differential Alarm Delay
Defrost Cycle Time
d8
Intervals
Maximum Defrost
d9
Duration
Defrost Cut-off
d10
Temperature
Additional Cut-off
d11
Defrost Period
Delayed Actual
d12
Temperature Display
Compressor On/Off
d13
During Defrost
d14
Evaporator Drying Time
=19
Temperature Offset
=22
Unit of Measurement
Compressor Operation
=23
During Probe Failure
Compressor 'On'
=24
Duration
Compressor 'Off'
=25
Duration
Initial Defrost After
=34
Startup
Minimum Temperature
=38
Alarm
3
button until 'd1' flashes on the display.
button repeatedly to scroll to the desired parameter (see "Parameter Descriptions" for parameter details).
Set the operating temperature of the appliance
The Temperature Differential is the allowed temperature difference above and below
the operating temperature before the compressor starts/cuts off
Set the minimum (d3) and maximum (d4) temperatures that the appliance can
fluctuate between
Enter the minimum time interval between the compressor turning off after turning on 0-999 seconds
Set an alarm to sound if the temperature inside the appliance exceeds the set
operating temperature by a specified amount
Set a delay before the temperature differential alarm is triggered
Set the time between each defrost cycle
Set the maximum length of the defrost cycle
Note: The defrost duration can be overridden by parameter d10 (below), if
the cut-off temperature is reached before the end of the defrost duration
Set the defrost cut-off temperature
Set an additional amount of defrost time after the defrost cut-off point has been
reached (if required)
Set the length of time the inner temperature of the appliance (before defrost started)
is displayed for after a defrost cycle has finished
Turn the Compressor On or Off during the defrost cycle
Set the amount of time the compressor remains turned Off after a defrost cycle,
reducing the amount of frost build up
Should there be any variance between measured and actual temperature, the
measured temperature can be offset to compensate
Set whether the temperature is displayed in Centigrade or Fahrenheit
Set whether the compressor runs or remains Off during a temperature probe failure
Set the length of time the compressor runs during a temperature probe failure
Set the length of time the compressor remains Off during a temperature probe
failure
Set whether the appliance starts a defrost cycle 10 minutes after startup or after the
time programmed in parameter d8 (Defrost Cycle Time Intervals)
Set the display to flash should the inner temperature of the appliance drop beyond a
specified point from the programmed operating temperature
and DOWN
buttons.
Description
Range
(dependant on model)
-2°C to 10°C
0 to 20°C
-40°C
95°C
0°C-50°C
0-99 minutes
1-999 hours
0-999 minutes
-45°C to 50°C
0-99 minutes
0-99 minutes
On (1) or Off (0)
0-99 minutes
-20°C to 20°C
Centigrade (0) or Fahrenheit (1)
Compressor runs (1)
Remains Off until fault fixed (0)
Runs intermittently with
parameters =24 and =25 (2)
1-99 minutes
1-99 minutes
Begins 10 minutes after startup
(0) or when programmed (1)
1°C to 50°C