• RAID FPGA: Internal temperature of the FPGA on the
MB-1204 board
Error/Warning
Displays errors and warnings that occur in the system.
The following major error messages are displayed.
ID
Message
0101,
POWER
0102
SUPPLY [A/B]
ERROR
0111 to
FAN [1-5]
0115
ERROR
0121 to
HDD [1-12]
012C
ERROR
0131
HIGH
TEMPERATURE
0132
HIGH
TEMPERATURE
0133
HIGH
TEMPERATURE
0134
HIGH
TEMPERATURE
0141
LOW BATTERY
0151
DIO-98 INITIAL
ERROR
0152
SMBUS ERROR An error occurred on the
0153
EEPROM
ERROR
The following major warning messages are displayed.
ID
Message
0201,
POWER
0202
SUPPLY [A/B]
WARNING
0211 to
FAN [1-5]
0215
WARNING
0221 to
HDD [1-12]
022C
WARNING
a) Only if an HDD is installed in the unit
Log Collection
When you click the [Output] button, a PWS-100 log file
(Maintenance Web Application log and disk information
for the PWS-100) will be saved to the following folder.
C:\Users\Default\AppData\Local\Sony\PWS-100\logs\
[Output Directory]
Description
A power supply error was
detected in the power supply
unit.
A fan failure was detected.
a)
An HDD error was detected.
The temperature inside the unit
(CPU) is high.
The temperature inside the unit
(MB board) is high.
The temperature inside the unit
a)
(storage) is high.
The temperature inside the unit
(MSQ-S321) is high.
The backup battery voltage is
low.
Initialization of the DIO-98
board failed.
SMBUS I/F of the MB-1204
board.
An error occurred on the
EEPROM I/F of the MB-1204
board.
Description
The speed of the power supply
fan has dropped.
The speed of the fan has
dropped.
The number of HDD read/write
a)
errors is increasing.

Settings Page

This page is used to change system settings.
Menu Settings
001 LINE LED
Specifies whether the front panel LED is on/off.
• ON: LED is lit (default).
• OFF: LED is not lit.
002 REDUNDANT PSU
Specifies whether an optional power supply unit is
installed for power supply redundancy.
• ON: Installed.
• OFF: Not installed (default).
Click the [Save] button to apply the settings.
SNMP Settings
Specifies SNMP settings.
• Community Name: Specifies the SNMP community
name (up to 16 characters). The default setting is
"public."
• Host IP Address: Specifies the IP address of the SNMP
host. The default setting is "127.0.0.1."
• Trap IP Address: Specifies the IP address of the trap
destination.
• SYS CONTACT: Specifies contact information (up to
255 characters) for the system administrator.
• SYS NAME: Specifies the system admin name (up to
255 characters).
• SYS LOCATION: Specifies the system location (up to
255 characters).
Click the [Save] button to apply the settings.