Coaxial Duct (Ø 60/100Mm And Ø 80/125Mm); Separate Ducts (Ø 60Mm And Ø 80Mm) - Sime BRAVA SLIM HE 25/55 Manual De Instalación Y Mantenimiento

Calderas murales de condensación con calentador-acumulador
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.12.1 Coaxial duct (Ø 60/100mm and Ø 80/125mm)
Coaxial accessories
Description
Coaxial duct kit
Extension W. 1000 mm
Extension W. 500 mm
Vertical extension W. 140 mm with
smoke analysis take-off point
Adapter for Ø 80/125 mm
Additional 90° curve
Additional 45° curve
Tile with joint
Roof outlet terminal W. 1284 mm
Load loss - Equivalent lengths
Model
90° curve
45° curve
Minimum-Maximum Lengths
Model
Horizontal
Min.
Brava Slim HE 25/55
-
ErP
Brava Slim HE 30/55
-
ErP
2.12.2 Separate ducts (Ø 60mm and Ø 80mm)
Constructing outlets for separate ducts indicates the use of the
"air-flue split pipe system". This is to be ordered separately
from the boiler and when connected to the other accessories,
from those listed in the table below, completes the smoke-
outlet/ combustion air inlet assembly.
Separate accessories
Description
Air-flue split pipe system (without take-
off point)
Air-flue split pipe system (with take-off
point)
90° curve M-F (6 pieces)
90° curve M-F (with take-off point)
M-F 80/60 reduction
Extension W. 1000 mm (6 pieces)
Extension W. 500 mm (6 pieces)
Extension W. 135 mm (with take-off
point)
Wall outlet terminal
Internal and external ring nut kit
Inlet terminal
45° curve M-F (6 pieces)
Manifold
Tile with joint
Roof outlet terminal W. 1390 mm
Inlet/outlet fitting Ø 80/125 mm
82
Code
Ø 60/100
Ø 80/125
mm
mm
8096250
8096253
8096150
8096171
8096151
8096170
8086950
-
8093150
8095850
8095870
8095950
8095970
8091300
8091300
8091205
8091205
Leq (linear metres)
Ø 60/100 mm
Ø 80/125 mm
1,5
2
1
1
Duct Length Ø
Duct Length Ø
60/100
80/125
W
H
W
Vertical
Horizontal
Vertical
(m)
(m)
(m)
Max.
Min.
Max.
Min.
Max.
Min.
6
1,3
8
-
12
1,2
6
1,3
7
-
10
1,2
Code
Diameter Ø
Diameter Ø
60 (mm)
80 (mm)
8093060
-
8093050
8089921
8077450
8089924
8089923
8089920
8077351
-
8077350
-
8077304
8089541
8089501
8091510
8091500
8089540
8089500
8089922
8077451
8091400
8091300
8091204
-
8091210
Split pipe system
2
1
-
KEY:
Split pipe system with take-off point
1
Air inlet
2
Smoke outlet
3
Take-off point for smoke analysis
4
m
CAUTION
– The maximum total length of the ducts , obtained by
adding the lengths of the inlet and outlet pipes,
is determined by the load losses of the individual
H
accessories used and must not exceed 15 mm H2O .
(m)
– For all boiler versions, the total extension must not in
Max.
any case exceed 25 m (inlet) + 25 m (outlet) for ducts
Ø 80 mm
15
(inlet) + 6 m (outlet) for ducts Ø 60 mm , even if the
total load loss is less than the maximum which can
13
be applied.
Load loss accessory Ø 60 mm
Description
Air/smoke split pipe
system
90° curve MF
45° curve MF
Horizontal extension
W. 1000 mm
Vertical extension W.
-
1000 mm
Wall outlet terminal
Wall inlet terminal
Roof outlet terminal (*) 8091204
-
(*) The losses of the roof outlet terminal at inlet include the
-
manifold code 8091400.
for the boiler to operate correctly it is necessary that a
NOTE:
minimum distance of 0.50 m of the duct is respected with a 90°
inlet curve.
3
4
. The total extension must not exceed 6 m
Load loss (mm H
Brava Slim HE
Brava Slim HE
Code
25/55 ErP
Inlet
Outlet
Inlet
8093060
2,5
0,5
8089921
0,4
0,9
8089922
0,35
0,7
0,45
8089920
0,4
0,9
8089920
0,4
0,6
8089541
_
1,2
8089540
0,5
_
0,8
0,1
EN
Fig. 15
O)
2
30/55 ErP
Outlet
2,5
0,5
0,5
1,1
0,9
0,5
1,1
0,5
0,7
_
1,4
0,8
_
1,1
0,15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Brava slim he 30/55 erp

Tabla de contenido