1.7

Sensors

The sensors installed have the following characteristics:
– Dual sensor (thermal safety/output) NTC R25°C; 10kΩ β25°-
85°C: 3435
– domestic hot water sensor NTC R25°C; 10kΩ β25°-85°C: 3435
– External temperature sensor NTC R25°C; 10kΩ β25°-85°C:
3435
Correspondence of Temperature Detected/Resistance
Examples of reading:
TR=75°C → R=1925Ω
TR=80°C → R=1669Ω.
TR
0°C
1°C
2°C
3°C
4°C
0°C 27279
26135
25044
24004
23014
10°C
17959
17245
16563
15912
15289
20°C
12090
11634
11199
10781
10382
30°C
8313
8016
7731
7458
7196
40°C
5828
5630
5440
5258
5082
50°C
4161
4026
3897
3773
3653
3021
2928
2839
2753
2669
60°C
70°C
2229
2164
2101
2040
1982
80°C
1669
1622
1577
1534
1491
1266
1232
1199
1168
1137
90°C
100°C
973
1.8

Expansion vessel

The expansion vessel installed on the boilers has the following
characteristics:
Description
U/M
Total capacity
l
kPa
Prefilling pressure
bar
Useful capacity
l
Maximum system
l
content (*)
(*) Conditions of:
Average operating temperature 70°C (with high
temperature system 80/60°C)
Start temperature at system filling 10°C.
m
CAUTION
– For systems with water content exceeding the
maximum system content (as indicated in the
table) an additional expansion vessel must be
prearranged.
– The difference in height between the relief valve
and the highest point of the system cannot exceed
6 metres. If the difference is greater than 6 metres,
increase the prefilling pressure of the expansion
vessel and the system when cold by 0.1 bar for each
meter increase.
5°C
6°C
7°C
8°C
9°C
22069
21168
20309
19489
18706
14694
14126
13582
13062
12565
9999
9633
9281
8945
8622
6944
6702
6470
6247
6033
4913
4751
4595
4444
4300
3538
3426
3319
3216
3116
2589
2512
2437
2365
2296
1925
1870
1817
1766
1717
1451
1411
1373
1336
1300
1108
1079
1051
1024
998
Brava Slim HE ErP
Heating
Hot water
10
2,5
100
100
1,0
1,0
6,0
-
140
-
1.9

Circulation pump

The flow-head performance curve available for the heating
system is shown in the graph below.
RESIDUAL HEAD (mbar)
600
500
400
300
200
100
0
0
200
400
m
CAUTION
The appliance is equipped with a by-pass which
ensures water circulation in the boiler when the
thermostatic valves or cocks are used in the system.
30
25
600
800
1000
1200
FLOW (l/h)
Fig. 5
75

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Brava slim he 30/55 erp

Tabla de contenido