Start-Up Instructions; Prior To Start-Up - Astralpool VICTORIA PLUS SILENT VS Manual De Instrucciones

Ocultar thumbs Ver también para VICTORIA PLUS SILENT VS:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
- Respect the electrical installation and connection instructions. Failure to do so may lead to the pump's
manufacturer declining all liability and rendering the warranty null and void.
- The installation may be subject to special regulations.
- Unsuitable mains connections involve the risk of electrocution.
For this motor, the following points must be considered:
• Thermal protection is incorporated.
• Use a motor guard with magneto-thermal protection.
• The adjustment data for the thermal relay is to be used as a guideline only, as the motor is already fitted
with protection.
• For 230 V, use an H07 RN-F3 type connection sleeve with a cable section that adapts to the power of the
motor and to the length of the cable.
• For AC, use an H07 RN-F3 type connection sleeve with a cable section that adapts to the power of the
motor and the length of the cable.
• The mains cable may only be connected by skilled, authorized personnel.

4. START-UP INSTRUCTIONS

PRIOR TO START-UP

- Measurements prior to first start-up:
1. Remove the pre-filter cap by unscrewing the nut holding it in place (Fig. 5).
2. Fill the pump with water through the pre-filter until it rises up through the suction pipe.
3. Should the basket be removed during these operations, do not forget to replace it to prevent large
particles from entering the pump that could block it.
4. Check that the mains voltage and frequency correspond with those indicated on the pump's rating
plate.
- Fit the pre-filter cap and screw on tightly, without forgetting to fit the seal in its housing (Fig. 5).
- The pumps must not be run without the pre-filter having first been filled with water. Where this is
not the case, the mechanical gasket may be damaged, leading to a loss of water.
START-UP
- Open all the valves and connect the motor.
- Activate the self-priming mode and wait a reasonable time for this to be completed.
Installation and general maintenance manual