ENGLISH
28
Problem
The brew group cannot
be inserted.
Coffee does not have
enough crema or it is
watery.
Coffee drops leak from
the dispensing spout.
Coffee is not hot
enough.
The machine grinds
coffee beans, but the
coffee is not dispensed.
Coffee is dispensed
slowly.
4219-450-03601 MANUAL GAG. ANIMA CLASS-PREST. EN-ES-PT.indd 28
Cause
The brew group is not in its correct
position.
The machine is still performing the
descaling cycle.
The coffee grinder is set to a
coarse grinding.
The coffee blend is not suitable.
The machine is performing the
autoregulation operation.
The brew group is dirty or it needs
lubrication.
The coffee dispensing spout is
clogged.
The coffee outlet duct is clogged.
The cups that have been used are
cold.
The set temperature is too low.
Check the menu settings.
You have added milk.
The coffee outlet duct is clogged.
The coffee grinder is set to a too
fine grinding.
The brew group is dirty.
The coffee dispensing spout is
dirty.
The coffee grinder is set to a too
fine grinding.
The brew group is dirty.
The coffee outlet duct is clogged.
The machine circuit is clogged by
limescale.
Solution
The brew group has not been placed in its
right position before being put back. Ensure
that the lever is in contact with the base of the
brew group and the hook of the brew group is
in its right position (see: "Reinserting the Brew
Group").
To reset the machine: put the drip tray and
the coffee grounds drawer back. Do not inset
the brew group. Close the maintenance door,
switch off the machine and switch it on again.
Try to reinsert the brew group.
When the descaling procedure is enabled, the
brew group cannot be removed. Wait for the
descaling procedure to end, then remove the
brew group.
Adjust the coffee grinder to a finer grinding.
Change the coffee blend.
Prepare some cups of coffee.
Clean the brew group.
Clean the coffee dispensing spout and its
holes with a bottlebrush.
Clean the coffee outlet duct.
Pre-heat the cups washing them under hot
water.
Set the menu temperature to "MAX".
Adding hot or cold milk always lowers the
coffee temperature to some extent.
Clean the coffee outlet duct using the handle
of the measuring scoop or the handle of a
spoon. Switch off the appliance and switch it
on again.
Set the coffee grinder to a coarser grinding.
Clean the brew group.
Clean the coffee dispensing spout and its
holes with a bottlebrush.
Use a different coffee blend or adjust the
coffee grinder.
Clean the brew group.
Clean the coffee outlet duct using the handle
of the measuring scoop or the handle of a
spoon.
Perform the descaling.
03/12/2018 15:01:37