G
B
A - CONTROL PANEL FEATURES
J12
J11 J10
PROG
SENS
RUN
TCA
LOW SP
Power supply 230 Vac 50/60 Hz - external to the control panel -
J1
N F
(120 V 60 Hz upon request)
A+TEST
+ 24Vdc photocells self-test power supply
J2
A-
- 24Vdc accessories power supply
A+ COM
+ 24Vdc accessories power supply
COM A+
Common contacts / Positive 24 Vdc
J3
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
COM A+
Common contacts / Positive 24 Vdc
J4
STOP
STOP impulse contact (NC)
PHOTO 1
Photocells contact 1 (NC)
PHOTO 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
Radio Antenna 433MHz
J5
R-AUX
Auxiliary relay contact (NO) Max 700 W
Gate open state and battery state output indicator (24 Vdc 3
SIGNAL -
W max)
LOCK -
Electric lock connection (MAX 15W 12V)
24Vdc blinker (code ACG7072) power supply. Pay attention to
the polarity.
COM A+
Common contacts / Positive 24 Vdc
J9
J8
J13
J14
36
J7
J6
J15
RADIO
Connector for radio module ACG8069
J6
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J7
BATTERY CHARGER
J8
Connector for charge card of 24 Vdc battery (code ACG4773)
(24 V DC SOLAR)
SERIAL COM /SYNC Connector for serial connection
J9
APP+
Connector for APP+ card
J10
APP
Connector for APP Card
J11
RS485 termination of J10
J12
MOTOR 2
MOTOR 2 CONNECTION (without polarity)
J13
MOTOR 1
MOTOR 1 CONNECTION (without polarity)
J14
SECONDARY
J15
Connection to secondary coil of transformer 18 Vac
TRANSFORMER
SENS
Trimmer for adjusting sensitivity to impact against an obstacle
Trimmer for automatic closing time adjustment (DISABLED BY
TCA
FACTORY AND DL11 LED OFF)
RUN
Trimmer for high speed adjustment operations
LOW SP
Trimmer for low speed adjustment operations
PROG
Programming button
T 2 A
Transformer protection fuse (external to the card B2D 24V)
F1
T 8 A
Motors protection fuse
F2
J2
J3
J5
J4
J1
F2
F1
F
N