Descargar Imprimir esta página

RIB PRINCE 24V Manual Del Usuario página 33

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Comply with the measure and make
sure that the operator is horizontal
In order to carry out a proper installation of the
operator, it is necessary to comply with the
geometry measurement shown in the tables
below.
Respect the measures for a correct installation
A
a
L
mm
mm
108°
0
105°
20
103°
40
99°
60
100
1-3m
99°
60
97°
80
95°
100
125°
0
140
112°
20
Measures WITH 2 MECHANICAL STOPPERS
A
a
L
mm
mm
108°
0
105°
20
103°
40
100
99°
60
1-3m
99°
60
97°
80
120°
0
140
107°
20
C
D
T
*
mm
sec
15
17
A
18
19
765
19
20
22
B
21
21
C
D
T
*
mm
sec
18
20
A
21
22
730
21
23
B
23
23
C
α
If the pillar is too large, and it is not possible to adjust the actuator
complying the measurements (B), you must make a niche in the pillar
or you have to move the gate closer to the edge of the pillar.
OUTSIDE OPENING with 2 STOPPERS
OPENED
9
33
L
A
B
* Leaf attachment
PRINCE
730
CLOSED
387
G
B

Publicidad

loading

Este manual también es adecuado para:

1 503 019Ad00738Aa14031Kit prince 24v