INSTALLATION PRINCE
PRE-INSTALLATION CHECK LIST
The gate leaves must be firmly fixed to the hinges on the gate pillars, they must not flex during
the movement and they must swing without any friction.
Before installing the operator, make sure you have enough room to fix the operator on the pillar.
In case the gate is like the one depicted in Pic. 1, there is no need for any modification.
Gate features and installation must comply with local regulations and standards.
The gate can be automated only if it is in good conditions and complies with EN12604 norms.
The gate leaf must not have a pedestrian doors in its frame. Should there be a pedestrian opening,
take the appropriate steps according to EN12435 norms (e.g. cutting out the motor when the
pedestrian door is opened by fixing a safety micro switch connected to the control board).
Make sure not to create any trapping points or areas (e.g. with the gate completely opened,
between any opening in the gate frame and the side wall).
Parts to install according to EN 12453 standard
COMMAND TYPE
(out of public area*)
Hold-to-run operation
Impulsive - in sight
(e.g. push-button)
impulsive - out of sight
(e.g. remote)
automatic
* a typical example are those doors which do not have access to any public way
A: Hold-to-run operation made by push-button ex: code ACG2013
B: Hold-to-run operation made by key selector ex: code ACG1010
C: Adjustable power of the motor or photocells to respect impact forces as indicated in
Annex A
D: Safety strips and/or other additional devices to reduce the probability of contact with
the door.
E: Devices installed in such a way that a person can not be touched by the door.
EMERGENCY MANUAL RELEASE
This applies only if the unit is not equipped with back-up batteries. In case of a black-out, the
gate can be pulled open after the operator has been unlocked with the emergency key provided
(rotate the key by 90° clockwise, Pic. 3).
Caution
In order to be able to manually open the gate leaf make sure of the following:
- The gate leaves must be endowed with appropriate handles;
- Position of the handles onto the gate leaves must be in risk free area;
- The manual force necessary to move the gate leaves should not be higher than 225 N, in case
of installations at domestic/private dwellings, and 390 N in case of installations in business
premises (according to points 5.4.5 of the EN 12453 norm).
Note: in case of an installation with an overlapping two leave swing gate to ensure a safe/proper
locking a mechanical bolt must be installed along with an electric lock. The mechanical bolt
(ACG5000) must be installed at the bottom of the first gate leaf to close so that it will be
simply operated by the pressure of the second gate leaf. The electric lock will simply latch
one gate leaf to the other.
FIXING THE ACTUATOR ATTACHMENT TO THE COLUMN
To obtain a correct movement of the gate leaf, it is necessary to comply with the measurements
given (Pic. 4, 5, 7, 8, 9)
In case an iron pillar is available, weld the bracket straight to it.
In case you need to fix the bracket onto a concrete pillar, use the fixing plate as shown in picture
4, that will have to be fastened with 4 Fischer screws of Ø 8 mm.
In case you have a wall parallel to gate leaves when in open position, you must allow for a niche
in which the operator can fit in.
FIXING THE ACTUATOR ATTACHMENT TO THE GATE
Weld the second bracket to the gate (pictures 6, 9)
During installation make sure to comply with the measurements mentioned in the table below.
Fix the PRINCE and try several times to open and to close the gate, controlling that the cover does
not touch the moving gate.
USE OF THE SHUTTER
Skilled persons
Skilled persons
(public area)
A
B
C or E
C or E
C or E
C and D, or E
C and D, or E
C and D, or E
Not skilled
persons
Not possible
C and D, or E
C and D, or E
C and D, or E
32
3
4
5
Grease
thoroughly
6
YES !
Be sure to tighten the bolt
that holds the bracket to
the operator so that it can
rotate freely.
NO !
The operator must not
vary its height during the
movement.
8