WIRING

WARNING: To reduce the risk of fire,
electrical shock, or personal injury, wire connectors
provided with this fan are designed to accept only
one 12 gauge house wire and two lead wires from
the fan. If your house wire is larger than 12 gauge
or there is more than one house wire to connect to
the two fan lead wires, consult an electrician for the
proper size wire connectors to use.
CAUTION: Be sure outlet box is properly
grounded and that a ground (green or bare) wire is
present.
WARNING: If house wires are different colors
than referred to in the following steps, stop
immediately. A professional electrician is
recommended to determine wiring.
DANGER: If using this fan in a DAMP location,
this fan must be connected to a supply circuit that is
protected by a Ground Fault Circuit Interrupter
(GFCI) to reduce the risk of personal injury,
electrical shock or death.
For each wire connection below, use one of the wire
1.
connectors (AA) provided, making sure to screw
wire connector (AA) on in a clockwise direction.
Connect BLACK and BLUE wire from fan to
BLACK wire from ceiling. Connect WHITE wire
from fan to WHITE wire from ceiling. Connect all
GROUND (GREEN) wires together from fan (on
downrod and mounting bracket) to BARE/GREEN
wire from ceiling. (Fig. 1)
Note: Black wire is hot power for fan. Blue wire is
hot power for light kit. White wire is common for fan
and light kit. Green or bare wire is ground.
FAN CONTROLLED BY PULL CHAINS
1
120 V Power
FROM
CEILING
FAN
GREEN
9
BLACK
WHITE
GROUND/GREEN (BARE)
WHITE
GREEN
BLACK
BLUE
WHITE
FROM FAN