Troubleshooting - Husqvarna 540i XP Manual Del Usuario

Ocultar thumbs Ver también para 540i XP:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

User interface
LED screen
Possible faults
The warning in-
Chain brake is
dicator flashes.
engaged.
Temperature
deviation.
Overload. The
saw chain can
not move.
The power trig-
ger and the
start/stop but-
ton are pushed
at the same
time.
Green activate
Low battery
LED flashing.
voltage.
The warning in-
Service.
dicator is on.
Battery
Problem
Green LED flashes.
Red error LED flashes.
Red error LED comes on.
Battery charger
LED display
Warning indicator flashing.
Warning indicator lit.
1065 - 002 - 13.05.2020

Troubleshooting

Possible solution
Disengage the chain brake.
Let the product to cool down.
Release the saw chain.
Release the power trigger to activate the product.
Charge the battery.
Speak to your servicing dealer.
Possible faults
Low battery voltage.
The battery is empty.
Temperature deviation.
Overvoltage.
Cell difference is to much (1V).
Possible faults
Temperature deviation.
Possible solution
Charge the battery.
Charge the battery.
Use the battery in temperatures between
-10°C (14°F) and 40°C (104°F).
Remove the battery from the battery charger.
Speak to your servicing dealer.
Possible action
Use the battery in surroundings
where temperatures are between
5°C/41°F and 40°C/104°F.
Turn to your servicing dealer.