Chamberlain MotorLift HC280ML Instrucciones De Instalación página 71

Ocultar thumbs Ver también para MotorLift HC280ML:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 97
Separate table for setting the operating modes
Standard
Standard &
no self-hold (hold to run) for closing
No self-hold (hold to run)
ACCESSORIES
PHOTOCELLS (OPTIONAL)
The photocells are for safeguarding the gate and must be used. The
fitting location depends on the gate's design. EN12453 specifies that
a pair of photocells must be installed at a height of 200 mm and
activated to "Close"; a second pair must be installed at a height of
200 mm and activated to "Open". A third pair of photocells can be
optionally installed and activated to "Close" and "Open". The
photocells consist of a transmitter and a receiver and must be
opposite each other. The housing of the photocell (plastic) can be
opened using a screwdriver. The photocell is mounted on the wall
using small screws and wall plugs. It is possible to use two different
photocell systems (see Dip switch description). To enable the
"Automatic Closing" function, the Chamberlain failsafe photocell must
be installed. A combination of photocells is not possible. The
Chamberlain failsafe system (2-cable system) has small LEDs (light)
that can be seen from the outside on both sides to indicate the status
of the photocell. Two Chamberlain failsafe photocell models are
available. The one model is ideal for walls lying opposite. The other
model is ideal for the inside of the gate, because fittings are already
available.
Diagnosis at the Chamberlain failsafe photocell
LED constant = OK
LED flashes = photocell disables control board
LED off = no current, incorrect connection or polarity
Diagnosis on the control board
LED off = OK
LED on constantly = control board disables
LED flashes = OK no photocell connected
Cable cross-section: 0.5 mm
Voltage: 12/24 volts AC/DC.
Do not use any fixed copper lines. Do not lay any 230 volt cables in
parallel and do not lay any 2 cables in the same cable trunking.
DIP1
DIP2
DIP3
ON
ON
OFF
ON
ON
OFF
OFF
OFF
OFF
2
or more.
Impulse transmitter/channel 1
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Impulse during closing stops
the gate
Impulse during opening stops
the gate
Impulse during the rest
closes the gate immediately
Gate closed:
1. impulse opens, the next
one stops, the next one
closes, the next one stops,
the next one opens etc.
Impulse during closing stops
the gate
Impulse during opening stops
the gate
Impulse during the rest closes
the gate immediately
Gate closed:
Permanent signal
required, letting go stops
Radio disabled, safety
equipment disabled
open/öffnen/ouvrir/open
close/schliessen/fermer/sluiten
open/öffnen/
ouvrir/open
Impulse transmitter/channel 2
Gate closed:
1. impulse opens gate 1
(pedestrian), the next one stops, the
next one closes, the next one stops,
the next one opens etc.
Impulse during closing stops the
gate
Impulse during opening stops the
gate
Impulse during the rest closes the
gate immediately
Gate open:
Permanent signal required for
closing, letting go stops
Radio disabled, safety equipment
disabled
Gate open:
Permanent signal required,
letting go stops
Radio disabled, safety equipment
disabled
close/schliessen/
fermer/sluiten
771EML

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido