Pratissoli KF Serie Manual De Uso página 26

Ocultar thumbs Ver también para KF Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Manufacturer
Lubricant
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and top up if necessary
Using the oil dipstick pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in chapter 11.
The quantity required is ~ 3.8 liters.
Set up the plant so that the oil temperature does
not exceed in any case 100 °C (212 °F) during pump
operation.
Use a temperature probe to be inserted into the oil
drain plug Pos.  Fig. 3.
See "ATEX EXPLOSION PROTECTION" manual.
ATTENTION: Use only oil with a flash point higher
than 200 °C.
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
Do not release used oil into the environment under any circumstances.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0 °C - 30 °C,
follow the instructions in the following diagram, considering
that oil must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
26
Fig. 3

Publicidad

Tabla de contenido
loading

Tabla de contenido