TROUBLESHOOTING

Error
Solution
All valves
1. Verify program: station time, watering start
will not
turn on
automatically
2. Check valve common wire for proper
3. Check for a shorted station; refer to
4. "How the electronic circuit breaker works"
5. Ensure rain sensor (if installed) is properly
6. Check fuse, replace if necessary. See p. 27.
Cannot
1. Disconnect power to controller for
program
2. Install fresh 9-volt alkaline battery.
3. Verify that all 16 start times are not in
Controller
1. Verify watering start times, current time
skips a cycle
No display
1. Check power source for tripped circuit
2. If program module has been removed, this
3. Disconnect power to controller for 1 min.
4. Replace battery
5. Check fuse, replace if necessary. See p. 27.
Troubleshooting
times, watering days schedule, current time,
current day, water budget and rain delay.
connection.
on page 5.
connected and functioning properly. If rain
sensor is not installed, ensure the
is in
SENSOR SWITCH
BYPASS
1 minute. Reconnect power and reprogram.
use by other programs.
and watering days schedule.
breaker.
is a normal battery-saving feature. Turn dial
to any position to reactivate display.
Reconnect power and reprogram.
position.