INSTALLATION PROCEDURES
MOUNTING THE CONTROLLER
INDOOR MODEL
1. Place the mounting template (provided) on the wall, positioning
the controller display area (indicated on the template) at or
slightly below eye level. Using a small punch or nail, mark the
locations of the top and bottom centerline mounting holes and
the additional lower hole if extra cabinet support is desired.
2. Drill pilot holes at least 1-1/4" (32mm) deep into the wall using a
3/32" (2.5mm) drill for wall stud, or 1/4" (6.5mm) for masonry.
3. For the masonry wall installation only, insert plastic screw anchors
into the pilot holes.
4. Install a #10 x 1" (25.4mm) phillips-head screw into the top hole
leaving 1/4" (6mm) of the shank exposed.
5. Open the cabinet door and swing out the control module by
pressing in on the release latch.
6. Using the keyhole slot, hang the controller on wall. Make sure the
screw shank slips into the top of the keyhole slot. Level the
controller and tighten the screw.
7. Install the lower screw(s).
8
Continue the wiring
installation procedures on
pages 21–23.
9. When all wiring is
complete, route the
transformer cord into the
controller and connect the
two leads to the screw
terminals marked 24 VAC.
10. Plug in the transformer
into a 120 V a.c. wall
outlet.
Installation Procedures
Figure 4
Indoor Model
19