7
COMMISSIONING
en
7.3

Sensing range setting

26
O P E R A T I N G I N S T R U C T I O N S | WTF16
White object, 90% remission, in front of white
4
background, 90% remission
Minimum object height in mm (y)
y
35
WTF16P-xxxxx4xx
3
30
90%/6%
25
20
1
6%/6%
15
2
10
6%/90%
5
4
90%/90%
0
0
100
200
300
400
500
600
(3.94)
(7.87)
(9.84)
(15.75)
(19.69)
(23.62)
Distance in mm (inch)
Figure 9: Characteristic line 2, WTF16P-xxxxx4xx, red
light
Black object, 6% remission, in front of black
1
background, 6% remission
Black object, 6% remission, in front of white
2
background, 90% remission
White object, 90% remission, in front of black
3
background, 6% remission
White object, 90% remission, in front of white
4
background, 90% remission
Minimum object height in mm (y)
y
24
WTF16P-xxxxx6xx
3
20
90%/6%
16
12
1
6%/6%
8
2
6%/90%
4
4
90%/90%
0
0
100
125
150
175
200
225
250
(3.94)
(4.92)
(5.91)
(6.89)
(7.87)
(8.86)
(9.84)
Distance in mm (inch)
Figure 10: Characteristic line 3, WTF16P-xxxxx6xx, red
light
Black object, 6% radiance factor, in front of
1
black background, 6% radiance factor
Black object, 6% radiance factor, in front of white
2
background, 90% radiance factor
White object, 90% radiance factor, in front of
3
black background, 6% radiance factor
White object, 90% radiance factor, in front of
4
white background, 90% radiance factor
WTF16x-xxxxxx2xAxx with Teach-Turn adjustment:
The sensing range is adjusted by pressing the teach-in button (approx. 1-3 sec.).
Depending on the requirements, the potentiometer can be used for fine-tuning (without
pressing the teach-in button). Clockwise rotation: Sensing range increased.
Clockwise rotation: Sensing range increased.
x
y
Background
x
Example:
Sensing range on black background, 6%,
x = 400 mm, y = 9 mm for white object
x
y
Background
x
Example:
Sensing range on black background, 6%,
x = 200 mm, y = 7 mm for white object
1
2
100
600
(3.94)
(23.62)
Distance in mm (inch)
D
C
A
B
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Viewing range
D
Adjustable switching thresh‐
old for foreground suppres‐
sion
E
Sensing range indicator
F
Teach-Turn adjustment
Sensing range on black, 6%
1
radiance factor
Sensing range on white, 90%
2
radiance factor
1
2
75
250
(2.95)
(9.84)
Distance in mm (inch)
D
C
A
B
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Viewing range
D
Adjustable switching thresh‐
old for foreground suppres‐
sion
E
Sensing range indicator
F
Teach-Turn adjustment
Schaltabstand auf Schwarz,
1
6 % Remissionsgrad
Schaltabstand auf Weiß, 90
2
% Remissionsgrad
8024126.1DS6/2021-11-24 | SICK
Subject to change without notice
BluePilot:
E
F
BluePilot:
E
F

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Wtf16

Tabla de contenido