Descargar Imprimir esta página

Fein Slugger JHM USA 101 X Instrucciones De Uso página 11

Ocultar thumbs Ver también para Slugger JHM USA 101 X:

Publicidad

Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000057-007.book Page 11 Friday, August 31, 2018 12:06 PM
Mounting the auxiliary handle
(figure 4).
Screw in and firmly tighten the auxiliary handle.
Filling the coolant container
(figure 5).
Prevent the flow of liquid
WARNING
along the cable into the
socket outlet or into the core drill unit, as this
can lead to electric shock. Tie a bow in the
cable near the plug, so that any liquid can drip
off.
Unscrew the cap from the coolant container.
Fill with water soluble cutting fluid like Slug-
ger Cutting Fluid.
Replace the cap back onto the coolant con-
tainer.
Do not use the magnetic core drill unit when
the cooling-lubricant system is defective. Each
time before operating, check for tightness
against leaks and for cracks in the hoses. Pre-
vent liquids from entering or penetrating elec-
trical components.
Auxiliary handle
Coolant container
en
11

Publicidad

loading

Este manual también es adecuado para:

7 272