Caution: once you have finished the operation, check that there are no gas leaks by testing with
soapy water or equivalent. DO NOT USE FLAMES TO TEST FOR GAS LEAKS.
GB - The appliance is supplied with cable without plug. A
standardised plug must be used bearing in mind that:
- yellow - green = earth
- blue
= neutral
- brown
= phase
ELECTRICAL CONNECTION
Before connecting the appliance to the mains, ensure that:
• The voltage corresponds to the voltage specified on the rating plate at the bottom of the
surround.
• The overload cut-off device and the domestic system can withstand the load of the appliance
(see rating plate).
• The power supply system is provided with an efficient earth connection and that the socket or
omnipolar switch, with minimum contact opening of 3mm., is easily accessible once the
appliance has been installed.
• If the plug is not easily accessible, the installation personnel must provide an omnipolar
switch with contact opening distance equal to or greater than 3 mm.
The power supply cable must be positioned so that it does not at any point exceed the ambient
temperature by 50°C.