TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar tecnomotor@tecnomotor.com.br
The available electrical conditions for the valves are:
• OK, when the valve is in normal electrical condition, ie able to perform the
test;
• OPEN, indicating the open state or no valve connected to the system;
• SHRT, indicating a short circuit condition on the valve or connection/cable;
• ERRO, indicating a valve with resistance outside the known range.
The equipment will only start a test if the valve is in Ok condition, ie, able to
mechanical test.
After the electrical test, CommonRailPC Fast software will start the test
automatically.
The system will perform pressure valve testing according to five specific test
points.
It is possible to follow the test done by TM 514 in CommonRailPC Fast, observing
the pressure variation generated.
When the test is over, the measured values will be displayed and can be saved in
a report.