Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar tecnomotor@tecnomotor.com.br
Minimum specification for informatics
• 2 Gigahertz (GHz) or higher 32-bit (x86) or 64-bit (x64) Multicore processor;
• 2 gigabytes (GB) of RAM (32 bits) or 4 (GB) of RAM (64 bits);
• 1 gigabyte (GB) of available hard disk space;
• DirectX 9 graphics device with WDDM driver 1.0 or higher;
• Mouse, keyboard and LCD monitor with a minimum resolution of 1024 x 768;
• USB 2.0 port for connection to equipment;
• Windows 7 or higher operating system;
• Access to the internet, for software and hardware update.
These devices have a fault detection system to identify operating problems during
the testing process, as well as irregular or forbidden actions such as opening a
safety cover during operation or connect any device shorted.
These defects are identified by a numerical code and a message as described in
the table below.
Some of the events are part of a complex set of equipment protection and user
and should be seen as such, therefore, proceed exactly as shown below if any of
these messages appear.
Before evaluating cases of errors, check that the firmware and software are up to
date.
Checking the internal parts of the machine must be carried out only by authorized
service personnel.
Erros
Error
1
Code
Probable Cause
- Accumulation of impurities in the hydraulic
system.
- Message occurs when the system can not
lower the pressure for some reason.
- Dirty DRV.
- Electrical activation of the DRV
compromised.
- Rail pressure sensor with wrong
measurement.
TM 514 – COMMON RAIL TEST
Defect codes table
Functional Error!
It is impossible to lower the rail pressure. Dirty DRV.
- Restart the machine and try the operation
again.
- Contact Technical Assistance to perform the
complete periodic maintenance.
230
Solution