TM 514 – COMMON RAIL TEST
Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar tecnomotor@tecnomotor.com.br
Back Leak Filter checking
Opening the Back leak Filter manually
1- Remove the Back Leak filter assembly from the machine, turning the filter
holder counterclockwise to release.
2- Turn the filter nut counterclockwise to open.
3- Be careful with the spring force when opening. Protect your eyes to avoid
accidents. When opening, remove the filter from inside the holder.
4- Clean the parts individually. Do not use fabrics or papers that can release lint
or particles.
Clean the filter with jets of air, water, solvents, descaling agents or ultrasound.
The use of acids is not recommended, as it may damage the filter cells.
If the filter is still clogged after cleaning, replace it.
Check the o-rings on the set. If any are broken or deformed, replace them.
NOTE: Open the filter assembly by unscrewing it with your hands. Do not
use wrenches or pliers to close the filter or install it on the machine, as
there is a risk of rupture of the o´rings.
ATTENTION: the use of the filter with the sintered element different from the
one supplied by TECNOMOTOR, dirty or obstructed can cause rupture of
the hoses and deviations of measurement values, as well as damage to the
measuring system and loss of warranty of the equipment.
Get in touch with TECNOMOTOR or with your country´s distributor in your
country, in order to get the filter.