Waeco CoolBreeze CB-1200-AC Instrucciones De Montaje página 44

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
IA_CB-1200.book Seite 44 Montag, 18. April 2005 4:15 16
Installing the fresh air cooling system
6.6.1 Adapting the connection shaft
➤ Insert the connection shaft (8 1) in the opening of the lower shell
casing of the fresh air cooling system.
Do not shorten the end of the connection shaft that is pushed onto the
suction hole of the fresh air cooling system.
➤ Now measure the distance "A" between the attachment unit and the
bottom edge of the connection shaft (8 2).
The distance must be approximately 36 mm. The connection shaft
must be shortened accordingly if the distance is greater than 36 mm.
Example of shortening the connection shaft:
Measured distance: 70 mm, required distance: approx. 36 mm
70 mm - 36 mm = 34 mm; the connection shaft has to be shortened by 34 mm.
➤ Apply an elastic, non-hardening butyl sealing compound to the edges
of the upper and lower connection shaft opening (8 1) and re-insert it
in the opening of the lower shell casing of the fresh air cooling system.
6.6.2 Installing the air outlet unit
To stabilize the connection between the connection shaft and the suction
hole, apply a small amount of butyl sealing compound to the contact surface.
➤ Insert the 4-pin plug of the connection line between the system and
fan into the socket on the circuit board (j 3).
➤ Insert the 2-pin pump plug in the socket on the circuit board
(j 1, page 10).
➤ Insert the 2-pin pump plug in the socket on the circuit board
(j 2, page 10).
➤ Connect the earth plug of the mains cable to the earth cable of the
system.
➤ Insert the 2-pin plug of the filling level sensor in the socket on the
circuit board (j 4, page 10).
➤ Slide the air outlet unit over the attachment frame.
➤ Attach the air outlet unit to the attachment frame with the 8 countersunk
self-tapping screws (4.9 x 24) (included in the scope of delivery).
Only for the CB-1200-AC/DC: Complete the installation procedure by installing
the inverter (see chapter "Inverter (only for the CB-1200-AC/DC)" on page 50).
44
All manuals and user guides at all-guides.com
(
9 ,
(
page 5)
8 ,
page 5)
CB-1200

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Coolbreeze cb-1200-ac/dc

Tabla de contenido