Inverter (only for the CB-1200-AC/DC)
8.7
Troubleshooting
The LED is lit green in the control panel of the fresh air cooling system
when the device is working properly.
If a fault occurs, the LED will be lit orange. This is due to one of the
following malfunctions:
Possible errors
No inverter output
voltage
Warning signal
during operation
No output voltage
in mains operation
(priority mode)
54
All manuals and user guides at all-guides.com
Cause
The battery voltage is below
9.9 V ± 0.2 V.
The inverter is overheated.
The fuse in the device is defective. Have an electrician replace the
The battery voltage is below
10.5 V ± 0.2 V.
Fuse 6.3 AT outside in the
insulated socket is defective (front).
CB-1200
Troubleshooting
Charge the battery
(start the engine).
Switch off the consumers.
Allow the inverter to cool down.
Provide better ventilation.
fuse in the inverter.
Charge the battery
(start the engine).
Replace the fuse 6.3 AT