Function Test Of The Cb-Ws-300 Inverter; Fault Indication - Waeco CoolBreeze CB-1200-AC Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
IA_CB-1200.book Seite 53 Montag, 18. April 2005 4:15 16
CB-1200
8.4.2 Connection on the fresh air cooling system
The fresh air cooling system is equipped with a 230 V mains cable (b 5,
page 6 or c 6, page 7) and an interface cable (b 6, page 6 or c 7,
page 7) for the inverter.
The respective safety socket (0 , 2) is located on the front side of the
inverter, and the interface connector (a , 4) on the rear side.
➤ Insert the plugs of the two cables in the respective sockets and make
sure they fit tightly.
8.5

Function test of the CB-WS-300 inverter

When connecting the connection terminals to the battery terminals, brief
sparking may occur, since the internal electrical capacities are being charged.
➤ Connect the negative connection cable first and then the positive
connection cable to the respective battery terminals.
➤ First switch on the inverter on the control panel of the fresh air cooling
system (see the operating manual) and the switch on the fresh air
cooling system (see operating manual).
Use the button "Inverter On/Off" on the control panel of the fresh air
cooling system to switch the inverter on or off.
The inverter is equipped with a 230 V priority circuit. If an external 230 V
mains voltage is available, the inverter voltage is disconnected from the
output socket of the inverter, and the socket
cooling system
voltage drops, the inverter must be switched on again with the "Inverter
On/Off" button on the operating panel. Now the system can be switched to
inverter mode.
8.6

Fault indication

The LED is lit green in the control panel of the fresh air cooling system
when the device is working properly.
If a fault occurs, the LED will be lit orange. This is due to one of the
following malfunctions:
Fault
Low voltage
High voltage Check the input voltage on the inverter and compare it with the
Excess
temperature
All manuals and user guides at all-guides.com
Inverter (only for the CB-1200-AC/DC)
is connected to the applied mains voltage. If the mains
Explanation
The remaining battery capacity is too weak. The batteries must be
recharged.
technical data of the inverter.
The inverter has become too hot. Check the ventilation. The
constant load may also be too high under the given circumstances.
Switch off the consumer unit and let the inverter cool down.
and thus the fresh air
53

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Coolbreeze cb-1200-ac/dc

Tabla de contenido