Installing The Unit In The Sunroof; Installing The Electrical Supply Lines - Dometic WAECO CoolAir RT880 Instrucciones De Instalación

Ocultar thumbs Ver también para WAECO CoolAir RT880:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 68
All manuals and user guides at all-guides.com
CoolAir RT880, SP950
6.2.4

Installing the unit in the sunroof

➤ Set the unit down centrally aligned and in the direction of travel
(fig. 1, page 3) on the sunroof opening.
NOTE
I
Make sure the air conditioning roof unit is centred perfectly. The seal must
be applied continuously around the air conditioning roof unit after being
placed on the roof of the vehicle. This is the only way to ensure a tight
seal.
➤ Place the spacer sleeve L = 48 mm (fig. 5 1, page 5) and (SP950
only) the washer M8 x 25 2 mm (fig. 5 9, page 5) on the fastening
drill holes as shown in fig. 5, page 5.
➤ Screw one hex screw M8 x 65 mm (fig. 5 4, page 5) with a washer
(fig. 5 2, page 5) and spring washer (fig. 5 3, page 5) in the 6
thread inserts on the bottom of the unit.
NOTICE!
A
Do not exceed the specified torque under any circumstances. This is the
only way to ensure that the thread inserts are not torn out.
➤ Tighten the screws with a torque of 8 Nm.
6.2.5

Installing the electrical supply lines

!
WARNING!
Make sure there is no voltage present on electrically operated compo-
nents before carrying out work on them!
I
NOTE
The unit is equipped as standard with a 4 m long cable with a cross-sec-
tion of 6 mm
section must be increased by an authorised specialist workshop:
In this case cut off the cable as closely as possible to the unit
(max. 0.5 m) and then establish a suitable connection with a larger cable
cross-section.
The manufacturer recommends a cross-section of 8 mm
between 4 m and 6 m long.
NOTICE!
A
 Fit a fuse of 25 amps to the connection to the vehicle's power supply.
 The battery must be able to supply the required current and voltage
(chapter "Technical data" on page 48).
EN
2
. If longer cable lengths are required, then the cable cross-
Installation
2
for cables
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Waeco coolair sp950

Tabla de contenido