MAHLE X20 System Guia Del Usuario página 27

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
MAHLE X20 System · Service
028
V.1.0.1 - 04/2022
SHORTCIRCUIT
182
Critical error of the BMS. If the problem
persists, go to your dealer.
OPEN_CELL_WIRE
183
Failure in the internal wiring of the battery.
Assistance level goes to 0. If the problem
persists, go to you dealer.
184
IMBALANCE_SEVERAL_CELL
Severe imbalance between cells.
Assistance level goes to 0. Please perform
a full charge of the battery as soon as
possible.
PACK_OVERTEMPERATURE
185
High battery temperature. The battery cells
are suffering severe degradation from high
temperature. Assistance level goes to 0.
Please go to a cooler place.
PACK_UNDERTEMPERATURE
186
Low battery temperature. The battery cells
are suffering and degradation from low
temperature. Assistance level goes to 0.
Please go to a warmer place for better cell
life.
PACK_OVERTEMPERATURE_CHARGING
187
The temperature is too high to charge the
battery. Assistance goes to 0. Please goes
to a cooler place for better cell life.
PACK_UNDERTEMPERATURE_CHARGING
188
The temperature is too low to charge the
battery. Assistance goes to 0. Please go to
warmer place for better cell life.
OVERVOLTAGE_PROTECTION_PACK
189
Battery pack voltage is more than the max
allowed. Please stop the charging process
and try to discharge it.
UNDERVOLGATE_PROTECTION_PACK
190
Battery pack voltage is less than the
minimum allowed. Assistance level goes 0.
It is recommended to charge the battery as
soon as possible.
OVERVOLTAGE_PROTECTION_CELL
191
Cell voltage is more than the max allowed.
Please stop the charging process and try
to discharge it.
UNERVOLTAGE_PROTECTION_CELL
192
Battery pack voltage is higher than the
maximum allowed. Assistance level goes
to 0. It is recommended to charge the
battery as soon as possible.
FET_OVERTEMPERATURE
193
BMS MOSFET temperature failure. If the
problem persists, go to your dealer.
HMI_1_OVERLOAD_OR_SHORTCIRCUIT
194
There is an overcurrent fault on the HMI 1
line. Assistance goes to 0 and power OFF.
Disconnect HMI 1 and connect the remote
to HMI 2 line.
195
HMI_2_OVERLOAD_OR_SHORTCIRCUIT
There is an overcurrent fault on the HMI 2
line. Assistance goes to 0 and power OFF.
Disconnect HMI 2 and connect the remote
to HMI 1 line.
MCON_OVERLOAD_OR_SHORTCIRCUIT
196
There is an overcurrent fault on the MCON
line. Assistance level goes to cero. If the
problem persists, go to your dealer.
FATAL_SOFTWARE_ERROR
197
Critical error of the BMS. Assistance goes
to 0. If the problem persists, go to your
dealer.
198
CAN_COMMUNICATION_ERROR
There are security errors in the BMS
communications. Assistance level goes to
0. Avoid using NON MAHLE original
equipment.
200
CRITICAL_ERROR
Critical communication in the BMS.
Assistance goes to 0. If the problem
persists, go to your dealer.
201
REVERSE_CURRENT
Reverse current error. Please check that
the motor is not breaking the eBike. If the
problem persists, go to your dealer.
Range Extender (RE)
Code
HMI
Description / Action
208
LOW_BATTERY_CELL
RE battery level too low for correct motor
operation. It is recommended to charge the
RE quickly. Assistance goes to 0.
209
LOW_BATTERY_PACK
RE battery level too low for correct motor
operation. It is recommended to charge the
RE quickly. Assistance goes to 0.
DERRATING_ACTIVE_CHARGING
210
High charging temperature. Please place
RE in cool environment for charging. To
avoid damage to the RE charging speed
has been slowed down.
DERATING_ACTIVE_DISCHARGING
211
High RE temperature. The RE cells are
suffering from high temperature. To ensure
safety, the motor power will be reduced.
Please switch off the RE or decrease assist
level to recover operation temperature.
212
IMBALANCE_LIGHT_PACK
Imbalance between RE cells. The capacity
of the range extender may be limited.
Please perform a full charge of the RD as
soon as possible.
221
CHARGE_OVERCURRENT
An overcurrent occurred while charging
process. Assistance goes to 0. Please
check that the charger and range extender
are in good condition. If error persist
replaces the hardware.