The structural features of TSKY-B products make them suitable for use on sectional or up-and-over doors, within the limits as specified in the
table.
Model
Guide
P-100BINBELT/CHAIN
P-100BINBELT3/CHAIN3
TSKY-B
P-100BINBELT350/CHAIN350
TSKY1-B
P-100BINBELT4/CHAIN4
Note: if art. P-100PROC (or P-100PROB) is used, the heights stated in the tables may be increased by 1m.
The measurements stated in the tables are guideline only and serve as a general estimate. The effective suitability of TSKY-B for the automation
of a specific door depends on the degree of leaf balance, friction on the guides and other factors, including occasional events, such as wind pres-
sure or the presence of ice, which may obstruct leaf movement.
2.2_ TYPE OF SYSTEM AND CABLE SECTIONS (FIGS. 3-4)
1_ Gearmotor with built-in
control
2_ Photocells
a_ 4x0,5 mm²
b_ 2x0,5 mm² + RG58
3_ INSTALLATION
TSKY-B must be installed by qualified personnel in compliance with current legislation, standards and regulations as well as the
specifications in these instructions.
3.1_ PRELIMINARY CHECKS
Before installing TSKY-B the following checks are required:
•
Ensure that all material used is in perfect condition, suitable for use and compliant with standards.
•
Ensure that the door structure is suitable for power-operation.
•
Ensure that the door has the force and dimensions within the application limits as specified in paragraph 2.1.
•
Ensure that the door complies with standards EN12604 and EN12605.
•
During movement, the door must never invade public areas allocated for the transit of pedestrians or vehicles.
•
During door travel, ensure that there are no points of marked friction, both during opening and closing.
•
Ensure sufficient strength of the mechanical stops and check that there is no risk of the door derailing.
•
Ensure that the door is adequately balanced, i.e. it should not move if left stationary in any position.
•
Ensure that the fixing points of the various devices (photocells, pushbuttons etc.) are located in areas protected against the risk of impact, and that the
fixing surfaces are sufficiently solid.
•
Ensure that the minimum and maximum clearances are as specified in figures 5 and 6.
•
Ensure that parts of the operator cannot come into contact with water or other liquids.
•
Do not keep TSKY-B components near sources of heat or expose to flames; these actions may damage or cause malfunctions, fire or hazardous situ-
ations.
•
If the door is equipped with a pedestrian pass door, ensure that this does not obstruct normal door travel; if necessary fit a suitable interlock system.
•
If the door to be automated is up-and-over, check value A of figure 7, i.e. the minimum distance between the upper edge of the guide and the maxi-
mum point reached by the upper edge of the door. Otherwise TSKY-B cannot be fitted.
•
Connect the TSKY-B power plug to an electrical socket equipped with safety earthing.
•
The electrical socket must be protected by an adequate thermal magnetic cut-out and residual current circuit breaker.
3.2_ SLIDING GUIDE ASSEMBLY
If supplied with the sliding guide in 3 sections, these must be assembled as described below:
1_ Straighten the three tracks after inserting the butterfly bracket on the section (for ceiling mounting), as shown in fig. 8
2_ Slide the joint to join the tracks (fig. 9) and secure using the screw (B fig. 9) suppied.
3_ Adjust the tension of the chain/belt by means of the chain tensioner nut (A fig. 9) until it is sufficiently taut.
Otherwise, if supplied with the pre-assembled guide, tension the chain/belt until it is sufficiently taut.
If the chain/belt is tensioned excessively, the motor will undergo excessive stress with a consequent increase in current absorption.
If the height of the door to be power-operated is greater than 2,5 m, the optional accessory 100PROC (for chain drive) or 100PROB (for belt drive)
is required to extend the sliding guide by 1 m. To assemble, proceed as follows:
• guide 100BINCHAIN3 – chain drive (100PROC)
1_
Insert the additional 1-metre section inside its joint of 700 mm (fig. 10).
2_
Keep the drive carriage locked in place (A fig. 11) and slide the chain until the joint protrudes (B fig. 11).
3_
Add the additional section on the chain (fig. 12).
4_
Slide the chain until it is locked on the drive carriage (fig. 13).
5_
Insert the additional section in the casing (with joint) and join the four tracks as described above (figs. 8-9).
6_
Tension the chain by means of the nut (A fig. 14) until it is sufficiently taut.
SECTIONAL
door
Height
2,3 m
2,8 m
3,3 m
3_ Photocells on post
4_ Sensitive edge
c_ 2x0,5 mm²
d_ 3x0,5 mm²
Model
Guide
P-100BINBELT/CHAIN
TSKY-B
P-100BINBELT3/CHAIN3
TSKY1-B
P-100BINBELT350/
CHAIN350
5_ Flashing light and aerial
6_ Key-operated selector switch
e_ 3x0,5 mm²
f_ 4x0,5 mm²
21
UP-AND-OVER
door projecting (with accessory
P-100BANT)
Height
2,7 m
3,2 m
7_ Pushbutton panel
8_ External release (optional)