Make settings
These settings must be made by a skilled person during the commissioning process.
All functions or settings can be made with either the Geberit App or the Geberit Service Handy. It is not
possible to make manual settings via the IR sensor.
Make settings using the Geberit Service Handy
The IR interface for communication with the Geberit Service Handy is located directly above the short button
on the right. To make settings, the Geberit Service Handy must be aimed at the IR interface from a distance
of 20 to 30 cm and set to bidirectional mode.
Figure 2: Operation using the Geberit Service Handy
The following functions and settings are available with the Geberit Service Handy:
• Operation:
– Flushing: Actuating a full or partial flush
– Cleaning: Suppressing the flush actuation for a few minutes
• Setting parameters and functions → See Table 1: 'Settings'
• Displaying device information → see Table 2: 'Information'
• Displaying statistical values for use → See Table 2: 'Information'
The numbers and terms in the 'Menu item' column in the following table correspond to what can be seen on
the display of the Geberit Service Handy. Further information can be found in the user manual of the Geberit
Service Handy.
Table 1: Settings
Menu item
Description
[EN]
[DE]
Commands
20
Release full flush volume
[FullFlush]
Releases a full flush.
[VollMenge]
21
Release partial flush volume
[PartFlush]
Releases a partial flush.
[TeilMenge]
9753440651 © 04-2022
970.779.00.0(00)
Application
• To carry out function
tests on the lifting
device
• To carry out function
tests on the lifting
device
Value
Factory
setting
Start = <OK>
Start = <OK>