geberit SIGMA80 Instructions De Montage página 48

Ocultar thumbs Ver también para SIGMA80:
Tabla de contenido

Publicidad

EN
Menu item
[EN]
[DE]
Parameter
40
[FlshTime]
[Spülzeit]
41
[IntervalT]
[IntervalZ]
42
[CleanTime]
[ReiniZeit]
43
[DetectRng]
[ErfassDis]
44
[DetectT]
[VerweilZ]
45
[DelayTime]
[Spülverzö]
46
[HygFlshT]
[HygFlshT]
40
Description
Sigma 12 cm: Flush time for full
flush volume
Sigma 8 cm: Flush time for
partial flush volume
The flush volume is set via the
flush time. (The specified flush
volumes are reference values and
depend on the WC ceramic
appliance.)
Flush interval for interval flush
The function of the interval flush is
determined by menu item 34.
Cleaning time
Defines the duration for which the
flush is suppressed when menu
item 23 [CleanMode] [Reinigung] is
started.
Size of WC ceramic appliance
The size of the WC ceramic
appliance is relevant for detection
of seated user.
Detection time
The minimum detection time in the
user detection range is set so that
users can be detected as a
standing or seated user. The
detection time is only relevant
when automatic flush actuation is
activated.
Flush delay
Once the user has left the user
detection range, a flush is not
actuated until the set time has
elapsed. The flush delay is only
relevant when automatic flush
actuation is activated.
Flush time for the interval flush
The function of the interval flush is
determined by menu item 34.
Application
• Optimum flushing of the
WC ceramic appliance
• To prevent flushes due
to unintentional entry of
a person into the user
detection range
Value
Factory
setting
Sigma 12 cm:
Full flush
volume
[0] = 4.5 l
[1] = 5 l
[2] = 5.5 l
[3] = 6 l
[4] = 6.5 l
[5] = 7 l
[2]
Sigma 8 cm:
Partial flush
volume
[0] = 2.5 l
[1] = 3 l
[2] = 3.5 l
[3] = 4 l
[4] = 4.5 l
1–168 h
24 h
1–20 min
10 min
[0] = short
[1] = medium
[1]
[2] = long
1–60 s
7 s
1–15 s
3 s
1–200 s
5 s
4 / 5
9753440651 © 04-2022
970.779.00.0(00)

Publicidad

Tabla de contenido
loading

Tabla de contenido