Menu item
Description
[Full flush]
This flush volume sets the time for
opening the flush valve for a full
flush. The specified flush volumes
are reference values and depend
on the WC ceramic appliance.
[Partial flush (statistics)]
[Flush volume
The flush volume of the partial
setting]
flush must be specified to
calculate the water consumption.
The flush volume of the partial
flush can be set on the flush valve.
[Flow pressure (statistics)]
The flow pressure in the supply
pipe must be specified to calculate
the water consumption.
Once the user has left the user
detection range, a flush is not
actuated until the set time has
[Flush delay]
elapsed. The flush delay is only
relevant when automatic flush
actuation is activated.
The minimum detection time in the
user detection range is set so that
users can be detected as a
[Detection time]
standing or seated user. The
detection time is only relevant
when automatic flush actuation is
activated.
9753440651 © 04-2022
970.779.00.0(00)
Application
• Optimum flushing of the
WC ceramic appliance
• For the statistics
function
• To calculate the flush
volume of the interval
flush
• For the statistics
function
• To calculate the flush
volume of the interval
flush
• For the statistics
function
• To calculate the flush
volume of the interval
flush
• To prevent flushes due
to unintentional entry of
a person into the user
detection range
Value
Factory
setting
4.5 l
5 l
5.5 l
6 l
6 l
6.5 l
1–5  l
2.5 l
0.5–10 bar
3 bar
1–15 s
3 s
1–60 s
7 s
3 / 5
45
EN