3.
EXAMPLE OF ...X... - MOTOR DATA PLATE (for flameproof models only)
Threephase
cosϕ
Power factor
I. Cl.
Motor insulation category
S1
Continuos service with motor completely submerged
S3
Intermittent service (in 10 minute cycles)
I.E.C. 60034-1
Standards used to establish the electrical characteristics
4.
PUMP CODING
Example : KCM065FA + 002521N3 / #####
Series
50 Hz ( S=60 Hz )
Single-channel impeller ( 1 )
DNm delivery port
Type / hydraulic size motor (electric centering)
Impeller diameter
Motor output power code (50 Hz) x 10 (0025=2,5 kW)
Nº Poles
Powering voltage code
Standard electric pump (X = flameproof)
Generational code
Miscellaneous specialties
Motor code match
( 1 )
Vortex impeller
5.
MOTOR CODING
(The motor data plate is only necessary on flameproof electric pumps)
Example: KC002521F090N3 / ####
Series
50 Hz ( S=60 Hz )
Motor output power code x 10 (0025=2,5 kW)
N° Poles
Powering voltage code
Type / hydraulic size motor (electric centering)
Surface motor frame size (ref. surface motor)
Standard motor (X = flameproof)
Generational code
Miscellaneous specialties
Associations with complete electric pump code
Caprari S.p.A.
K
C
M
065
F
: W
Single-channel impeller
K
C
0025
2
1
A
+
0025
2
1
: M
F
090
N
3
K..065F.. / K.T040F..
N
#####
3
Hydraulics with shredder: T
#####
GB