NOTES:
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
Pressing <-> with the display turned off means an impulse of P.P.
The tables below describe the individual functions available in the control unit.
MENU
Automatic closing time. Active only with logic "TCA"=ON.
TCA
At the end of the set time the control unit orders a closing manoeuvre.
Braking value of motor 1. The values indicate the brake percentage of the gate leaf (25%-
tsm1
50%-75%-100%) compared to the total opening/closing.
Braking value of motor 2. The values indicate the braking percentage of the gate leaf
tsm2
(25%-50%-75%-100%) compared to the total opening/closing.
Operating time of pedestrian gate leaf
Values which can be preset are:
TPED
25: 25% opening
50: 50% opening
100: 100% opening
PMo1
The torque applied to motor 1 during the opening phase is adjusted.*
PMC1
The torque applied to motor 1 during the closing phase is adjusted.*
PMo2
The torque applied to motor 2 during the opening phase is adjusted.*
PMc2
The torque applied to motor 2 during the closing phase is adjusted.*
Mot.2 opening delay time.
TDMo
Regulates the delay time of motor 2 on opening with respect to motor 1
Mot.1 closing delay time
TDMC
Regulates the delay time of motor 1 on closing with respect to motor 2
It regulates the motor 1 speed during braking. The value is expressed in percentage with
SLD1
respect to normal operating speed.
It regulates the motor 2 speed during braking. The value is expressed in percentage with
SLD2
respect to normal operating speed.
Pso1
The torque applied to motor 1 during braking in the opening phase is adjusted *
Psc1
The torque applied to motor 1 during braking in the closing phase is adjusted *
Pso2
The torque applied to motor 2 during braking in the opening phase is adjusted *
Psc2
The torque applied to motor 2 during braking in the closing phase is adjusted *
It adjusts the operating time of the service light when the "Service Light" logics is preset to
TLS
ON and the "2nd radio channel" logics is preset to OFF
Adjusts the inversion time after the intervention of the closing limit switch.
blcc
To be used in light doors to relieve pressure and avoid deformation.
Value expressed in tenths of a second 0: Off - 5: 0.5s.
Adjusts the inversion time after the intervention of the opening limit switch.
blco
To be used in light doors to relieve pressure and avoid deformation.
Value expressed in tenths of a second 0: Off - 5: 0.5s.
* WARNING: An incorrect setting of these parameters may result in an hazard. Comply with regulations in force!
To check the torque applied to the various phases of the operation, proceed as follows:
With switched-off display and moving gate leaves, press and keep the <+> key pressed
Two figures separated by a dot are displayed (e.g. 52.55), the first two figures indicate the torque applied to motor 1, while the last two the torque
applied to motor 2.
14
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
PARAMETERS (PAR)
FUNCTION
MEMO
MIN-MAX-(Default)
1-240-(40s)
25-100-(50)
25-100-(50)
25-100-(100)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
0-15-(2s)
0-40-(3s)
30-99 (50)
30-99 (50)
1-99-(20%)
1-99-(20%)
1-99-(20%)
1-99-(20%)
2s-180s-(60s)
0-5 (0)
0-5 (0)