7.6.

BATTERIES

PB-ACID
Carry out maintenance operations in accordance with
the manufacturer's instructions and with all the other
instructions provided in this manual.
Exposing the element plates (not completely immer-
sed in the acid solution) will lead to rapid oxidation
and irreparably reduce the element's operating ca-
pacities.
An overflowing acid solution may corrode the ma-
chine.
Use battery chargers recommended by the manufac-
turer and, in any case, those that are suitable for the
type of battery to be charged.
Always charge batteries in well-ventilated rooms:
there is an explosion risk!
The use of gel or maintenance-free batteries is highly
recommended.
GEL
Remove and wash the squeegee
Drain the recovery tank
Drain, rinse with clean water or sanificate the recovery tank
Charging of the batteries
Check the acid level in the battery cells (if batteries are not maintenance-free)
Check the wear of the squeegee rubber blades
Open and clean the suction filter
Remove brushes and check for brush wear, foreign bodies and wrapped belts
Verify the machine general conditions.
Open and clean the solution water filter
Verify that suction hose and conduct are free from obstructions
Check and clean the pivoting wheels
Check wear and function of traction drive belt or chain; if necessary, adjust
belt or chain tension
Clean the brush plate, squeegee support and squeegee
Check the lifting/lowering of the brush plate.
Check the lifting/lowering of the squeegee.
Grease the moving parts.
Check the control cable for the opening of the solution water tap.
Descale water hoses.
Carry out maintenance operations in accordance with
the manufacturer's instructions and with all the other
instructions provided in this manual.
Use only those battery chargers recommended by the
manufacturer.
☞ If the batteries are not used, in either case, for an
extended period of time, disconnect them and re-
store the charge within the time limits specified for
the type of battery used (generally and as a precau-
tion, no more than 3 months for Pb-acid/GEL/AGM
batteries, 6 months for Li-ion batteries).
The manufacturer accepts no liability for damage to
batteries caused by failure to follow this procedure.
7.7.

FUSES AND THERMAL BREAKERS

The machine is equipped with electric protection
devices on the main operating components to avoid
costly malfunctions.
Thermal cutouts are installed to protect the drive
motor wherever foreseen and the brush motor.
When one of these breakers trips automatically, the
disabled function can be reactivated by fully depres-
When
needed
X
X
34
After
Weekly
Monthly
every use
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X

Publicidad