Remote Control Battery; Maintenance Schedule - Champion Global Power Equipment CPG4000DHY-EU Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 124
CPG4000DHY-EU - 3500W WIRELESS REMOTE START OPEN FRAME INVERTER
Charge the Battery
For a generator equipped with batteries for electric starting,
proper battery maintenance and storage should be followed.
A trickle charger or battery maintainer should be used to charge
the battery while the generator is in storage. Maximum charging
rate should not exceed 1.5 amps. Follow the instructions included
with the trickle charger or battery maintainer. The battery should
be fully charged at least once per month.

Remote Control Battery

– Always purchase the correct size and grade of battery
most suitable for the intended use.
– Clean the battery contacts and also those of the device
prior to battery installation.
– Remove batteries from equipment which is not to be used
for an extended period of time.
– Remove batteries if consumed or if product is to be left
unused for a long time.

Maintenance Schedule

Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at +44(0)1942-715-407 to
locate the nearest CPE certified service dealer for your generator
or engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
— Check oil level
— Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
— Change oil
EVERY 50 HOURS OR ANNUALLY
— Clean air filter
— Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
— Change oil
— Clean/adjust spark plug
— Clean spark arrestor
— Clean fuel valve filter*
NOTICE
EVERY 250 HOURS
— Clean combustion chamber*
— Check/adjust valve clearance*
EVERY 3 YEARS
— Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should be
followed:
– When storing the generator make sure the START/STOP
button is "OFF" and not illuminated and fuel valve is set to
the "OFF" position.
Short Term Storage (up to 30 days)
Ethanol blended gasoline may gum up and clog the carburetor if
the generator is not run or carburetor drained within 4 weeks.
1. Be sure all appliances are disconnected from the generator.
2. Start the generator as instructed in Starting the Engine
section.
3. Turn the fuel valve to the "OFF" position.
4. Let the engine run until fuel starvation has stopped the
engine. This usually takes a few minutes.
5. If started using remote, press START/STOP button one more
time to ensure the generator is "OFF" and not in "STANDBY"
mode and blinking green.
Mid Term Storage (30 days – 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life
of up to 1 year with the addition of a properly formulated fuel
stabilizer and stored in a cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the "ON" position.
4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system.
5. Option 1: Drain Gasoline from Carburetor
5a. Turn off the generator by pushing the START/STOP
button. If started using remote, press START/STOP button
26
WARNING
STORAGE

Publicidad

Tabla de contenido
loading

Tabla de contenido