In cooling mode, the water temperature flowing
(TW_out) range in different outdoor temperature(T4) is
listed below:
-
Operation range by heat pump with possible limitation and protection.
In heating mode, the water flowing temperature
(TW_out) range in different outdoor temperature (T4) is
listed below:
In DHW mode, the water flowing temperature(TW_out)
range in different outdoor temperature(T4) is listed below:
4 BEFORE INSTALLATION
Before installation
Be sure to confirm the model name and the serial number of the unit.
Handling
Due to relatively large dimensions and heavy weight, the unit should only be handled using lifting tools with slings. The slings
can be fitted into foreseen sleeves at the base frame that are made specifically for this purpose.
3 ACCESSORIES
3.1 Accessories supplied with the unit
Installation Fittings
Name
Installation and owner's
manual(this book)
Operation manual
Technical data manual
Y-shape filter
Wired controller
Thermistor for domestic
hot water tank or zone2
water flow or balance tank
Drian hose
Energy label
Tighten belt for
customer wiring use
Network matching
wires
The thermistor can be used to detect temperature of
water.If domestic hot water tank is installed only, the
thermistor can work as T5. If boiler is installed only, the
thermistor can work as T1. If both unit are installed, an
addtional thermistor is needed(please contact the
supplier).The thermistor should connect to the
corresponding port in the main control board of
hydraulic(refer to 9.3.1Main control board of hydraulic
module).
06
Quantity
Shape
1
1
1
1
1
1
1
1
2
3
1