empty the recovery tank ( Photo 1 - B ) before filling
the solution tank ( Photo 1 - D ); in any case, a safety
float ( Photo 3 - B ) will stop the suction if the dirty
liquid level is too high
• If water or foam starts leaking from under the
tanks for any reason, immediately turn off the suction
motor and empty the recovery tank.
To drain the tank:
- Remove the recovery tank; to remove the recovery
A
Photo 30
A) Recovery tank drain plug
tank, detatch the suction hose from its siege ( Photo
4 - B ) and lift the tank by pulling it up as shown in
Photo 13.
- Carry the recovery tank to a suitable location to drain
the dirty water and preferably near a toilet or a sewer
drain (comply with the national regulations for waste
water disposal).
- Unscrew the recovery tank drain plug ( Photo 30 - A
) and empty the tank in the selected drainage point.
After the drainage of the recovery tank it is recom-
mended to check how much dirt is still in the tank
unscrewing the inspection cap ( Photo 3 - C ) and, if
necessary, wash it inside to remove the solid dirt.
- Once the drainage and the cleaning of the tank is fin-
ished, close the tank screwing the drain plug ( Photo
30 - A ) and the inspection cap ( Photo 3 - C ).
6. OPERATING INFORMATIONS
Solution water valve closed
Solution water valve partially opened
Solution water valve fully opened
44
Photo 31
Photo 32
Photo 33